Back to search

Freie Universität Berlin

Implantation of the novel AMD-stent in 100 patients with DeBakey type I acute aortic dissection

Abstract

dc:description.abstract

Background DeBakey type I aortic dissections are life-threatening emergencies, requiring surgeons to make critical decisions regarding aortic resection and cannulation. The AMDS (Ascyrus Medical Dissection Stent) aims to simplify surgery, improve true lumen flow, and encourage false-lumen thrombosis in the descending aorta. However, there is a lack of adequately powered studies on postoperative outcomes. This study compares early and midterm outcomes following surgery for acute DeBakey type I dissection, between classic hemiarch replacement and additional open noncovered stenting of the aortic arch. Methods Patients who underwent surgery for acute DeBakey type I dissection with either hemiarch replacement (2015-2022) or additional open noncovered stenting using AMDS (2018-2022) were included. After propensity score matching, clinical and radiological outcomes were compared between the groups. Results A total of 261 patients (155 hemiarch, 106 AMDS) were included. After matching, the cohort consisted of two balanced groups (108 patients, 54 per group). Thirty-day mortality was 19% in the hemiarch group versus 15% in the AMDS group (p=0.61, OR=0.77 [CI 0.27-2.12]). New postoperative stroke (p=0.99, OR=0.98 [CI 0.11-8.43]) and revision for malperfusion did not differ (p=0.38, OR=1.70 [CI 0.53-5.99]). The incidence of new distal anastomotic entries was significantly lower in the AMDS group (17%) versus the hemiarch group (45%) (p=0.028, OR=0.35 [CI 0.13-0.87]). True lumen expansion was significantly better in the aortic arch (p=0.006, OR=3.15 [CI 1.41-7.34]) and stented portion of the descending aorta (p<0.001, OR=8.51 [CI 3.65-21.24]), as well as false lumen thrombosis in the aortic arch (p=0.048, OR=2.24 [CI 1.02-5.07]). Two-year survival did not differ (p=0.170). Conclusions Additional AMDS implantation shows similar clinical outcomes, reduces the risk of new distal anastomotic entries, and may be associated with superior aortic remodeling in the aortic arch and stented portion of the descending aorta. Long-term data on aortic remodeling and reintervention rates are urgently needed.

Degree

thesis:*
Department dc:contributor.department
Charité - Universitätsmedizin Berlin
Year dc:date.issued
2025

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Seeber, Fabian
Committee member dc:contributor.committeemember
  • N.N.

Subjects

dc:subject × 4

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • open access
Language dc:language
eng

Identifiers

dc:identifier.*
URN
urn:nbn:de:kobv:188-refubium-48383-1

Chain of custody

source
Harvested from
Freie Universität Berlin
Base URL
refubium.fu-berlin.de/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Seeber, Fabian. Implantation of the novel AMD-stent in 100 patients with DeBakey type I acute aortic dissection. 2025. https://refubium.fu-berlin.de/handle/fub188/48383