Back to search

Freie Universität Berlin

Nichtinvasives Oszillometrie-basiertes hämodynamisches Monitoring versus invasives Monitoring auf der Intensivstation

Abstract

dc:description.abstract

Continuous monitoring of vital parameters is required in intensive and emergency care units to ensure optimal treatment. Today, invasive haemodynamic monitoring methods are well established in the intensive care unit to provide differentiated therapy for haemodynamically unstable patients. Invasive methods present a myriad of challenges that make them inappropriate for use outside the ICU. They are highly technical, require skilled medical staff and carry the risk of complications. The Mobil-O-Graph® (MG) uses a non-invasive oscillometric system to calculate CO by measuring blood pressure and analysing the pulse wave. In our work, we compared CO measured non-invasively by MG with CO measured with thermodilution method using the PiCCO® system. The study was performed in the intensive care unit of the Charité Benjamin Franklin. A total of 49 patients were included in the study. CO was measured before and after volume administration. In addition, the CO calibrated by PiCCO® was compared with the CO automatically measured every 20 minutes for a maximum of six hours. Statistical analyses were performed using IBM® SPSS statistical software. Results were presented as absolute and relative frequencies or as medians with quartiles. Differences between the MG and PiCCO® measurements were calculated using the paired sample Wilcoxon signed rank test. The median age of the patients was 73 years and 40% of the patients were men. HZVMG calculated with the MG was significantly lower than CO with the PiCCO® for both before (median 5.0 l/min vs. 6.0 l/min, p <0.001) and after (median 4.9 l/min vs. 6.2 ml/min, p = 0.004) volume administration. The percentage error was 71.5% and 79% before and after volume application, respectively. We observed a concordant increase or decrease in CO after volume administration in 34.3% of cases. The desire for a minimally invasive or non-invasive device for extended haemodynamic monitoring is considerable, but further improvements in device software and additional studies are considered necessary. Based on our results, non-invasive oscillometric CO measurement in the ICU is not sufficiently reliable.

Degree

thesis:*
Department dc:contributor.department
Charité - Universitätsmedizin Berlin
Year dc:date.issued
2025

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Gjolli, Jonida
Committee member dc:contributor.committeemember
  • N.N.

Subjects

dc:subject × 5

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • open access
Language dc:language
ger

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Freie Universität Berlin
Base URL
refubium.fu-berlin.de/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Gjolli, Jonida. Nichtinvasives Oszillometrie-basiertes hämodynamisches Monitoring versus invasives Monitoring auf der Intensivstation. 2025. https://doi.org/10.17169/refubium-49365