Back to search

Freie Universität Berlin

Adaptation of a W-Band EPR spectrometer to UHV conditions

Abstract

dc:description.abstract

The present PhD thesis describes for the first time the construction and preliminary tests of a system that allows electron paramagnetic resonance (EPR) measurements at 94 GHz (W-band) under ultra high vacuum (UHV) conditions and combines this technique with common surface science methods such as scanning tunneling microscopy (STM), infrared (IR) spectroscopy, low energy electron diffraction (LEED), thermal desorption spectroscopy (TPD) and Auger electron spectroscopy (AES). The main challenge of this work was an appropriate construction of an EPR resonator that fulfills the UHV conditions and simultaneously maintains a high sensitivity towards paramagnetic species. On the basis of theoretical considerations a Fabry-Perot resonator was selected. In particular, a resonator was chosen that consists of a concave and a planar mirror with the latter being simultaneously the sample under investigation. The adaption of this resonator to UHV conditions succeeded by placing a 150 µm thick quartz window between both mirrors. This, however, demanded that the second mirror was also placed under low vacuum to limit the forces acting onto the window. A number of challenges with this design were analyzed in detail and are described within the thesis. For example, a proper microwave coupling into the resonator is more complicated to achieve under the condition of vacuum on both mirror sites. Three different methods for adjusting the coupling were tested. Finally, a combined method of antenna coupling in vacuum and a three-screw tuner at ambient conditions was selected. Furthermore, the mechanical stability of the resonator proved challenging: Due to the spatial limitations in the magnet the concave and the planar mirrors are not in good mechanical and thermal contact. For this reason the system is sensitive to vibrations and thermal drifts. To reduce the coupling of vibrations into the system, the setup was built on an optical bench that is mounted on an active vibration isolation system. Temperature gradients in the laboratory led to detuning of the resonator that could not be compensated by the automatic frequency control (AFC) of the EPR spectrometer. A feedback loop was developed that uses the offset determined by the AFC to correct the position of the concave mirror with the help of a Peltier element. Furthermore, the influence of the quartz window on the resonator properties was analyzed in detail. It was shown that positioning the window close to the planar mirror is mandatory for optimum sensitivity. Additionally, it was proven that concave mirrors with higher radii of curvature led to better signal-to-noise ratios which is different from the window free case. The performance of the completed UHV assembly was tested on selected systems. The capability of the STM to produce atomically resolved images was proven on the reconstructed Si(111) surface. Furthermore, the morphological properties of thin magnesium oxide (MgO) films grown on Ag(100) could be reproduced. The MgO films were used afterwards to probe the adsorption behavior of N2O by infrared spectroscopy, and this investigation was compared to prior studies on MgO(100)/Mo(100). This comparison showed that the IR spectra of N2O reflect the different defect densities of the MgO films on the two substrates. The first UHV EPR spectra measured at W-band are the most significant results of the thesis. The measurements on the organic radical DTBN proved that the spectrometer adaptation to the pressure conditions succeeded and that paramagnetic species present in submonolayer quantities can be detected. Additionally, the measurements on MgO(100)/Mo(100) showed that paramagnetic centers on oxidic surfaces and interfaces can be investigated.

Degree

thesis:*
Department dc:contributor.department
Biologie, Chemie, Pharmazie
Year dc:date.issued
2010

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Kieseritzky, Esther (geb. Fischbach)
Committee members dc:contributor.committeemember
  • Prof. H.-J. Freund
  • Prof. K. Christmann

Subjects

dc:subject × 5

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • open access
Language dc:language
eng

Identifiers

dc:identifier.*
Dc Identifier Other
FUDISS_thesis_000000019572
FUDISS_derivate_000000008456

Chain of custody

source
Harvested from
Freie Universität Berlin
Base URL
refubium.fu-berlin.de/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Kieseritzky, Esther (geb. Fischbach). Adaptation of a W-Band EPR spectrometer to UHV conditions. 2010. https://doi.org/10.17169/refubium-9183