Freie Universität Berlin
Performance measure selection and optimization for automated cerebral artery segmentation
Abstract
dc:description.abstractIntroduction Cerebral vessel segmentation is utilized to extract clinically relevant information from cerebral vessel imaging. Recent advances in deep learning allow automated vessel segmentations without human intervention. However, the quality evaluation of cerebral vessel segmentation is still not standardized and there is only limited scientific consensus on the optimal choice of performance measures. Thus, the aim of this dissertation was to identify the most suitable performance measures for arterial brain vessel segmentation. In the first publication, a deep learning model for automated vessel segmentation in patients with cerebrovascular disease was developed. In the second publication, a novel distance-based performance measure coined balanced average Hausdorff distance (bAHD) was proposed by modifying the commonly used average Hausdorff distance (AHD). In the third publication, a performance measure selection framework was developed to find the most suitable measure for arterial brain vessel segmentation. Methods In Publication 1, a U-Net model using labeled time-of-flight MR angiography data from 66 patients with cerebrovascular disease was trained and evaluated. In Publication 2, a framework that allows the creation of simulated segmentation variations combining manually created vessel segmentation errors was developed. A ranking error of average Hausdorff distance (AHD) was identified and a new measure coined balanced average Hausdorff distance (bAHD) was proposed as an alternative, providing a better evaluation of vessel segmentation performance. In Publication 3, 22 performance measures from the literature were used to assess the quality of simulated segmentation variations. The correlation with a manual visual scoring system was calculated to select the optimal performance measures for arterial brain vessel segmentation. 3 Results In Publication 1, the U-net model achieved high performance in automated segmentation of cerebral arteries in patients with cerebrovascular disease. In Publication 2, the novel bAHD performance measure outperformed AHD in ranking segmentations based on their quality, ranked a lower number of segmentations incorrectly compared to AHD. In Publication 3, the distance-based performance measures bAHD and AHD had the highest average correlations with manual rankings and could identify more relevant segmentation errors, especially in high-quality segmentations compared to overlap-based performance measures. Conclusion The joint findings of the 3 publications presented in this thesis provide the basis for using customized performance measures for the task of arterial brain vessel segmentation. The use of more suitable measures and inherent standardization have the potential to accelerate the development and improve the validation of novel vessel segmentation approaches. Consequently, improved vessel segmentation can enable more accurate diagnosis of cerebrovascular diseases and aid in treatment decisions, ultimately leading to better patient outcomes.
Degree
thesis:*- Department dc:contributor.department
- Charité - Universitätsmedizin Berlin
- Year dc:date.issued
- 2026
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Aydin, Orhun Utku
- Committee member dc:contributor.committeemember
-
- N.N.
Subjects
dc:subject × 5Rights
dc:rights.accessrights- Statement dc:rights.accessrights
-
- open access
- Licence dc:rights.uri
- Language dc:language
- eng
Identifiers
dc:identifier.*- Identifier URI
- https://refubium.fu-berlin.de/handle/fub188/50273