Back to search

Freie Universität Berlin

Microscopic Magnetic Resonance Elastography

Abstract

dc:description.abstract

Magnetic resonance elastography (MRE) is a well-established imaging modality that is used to detect the biomechanical properties of soft tissue. While MRE is extensively used in both patient and preclinical studies, its potential is constrained by resolution limitations. These limitations are especially relevant when trying to understand and track the micro- structural causes of stiffness using histology, as the stiffness-constituting elements are much smaller than the resolution of current MRE sequences. We here hypothesize that high-resolution MRE with in-plane voxel sizes on the order of cellular dimensions is pos- sible and can provide meaningful comparisons with histological analyses. We then con- ducted three MRE studies at a 7-Tesla MRI scanner, demonstrating significant advances in spatial resolution. In a first study, a novel protocol for murine brain tumor characterization was established and applied to two tumor models, the B16 melanoma brain metastases model and the GL261 glioblastoma model, at 200 × 200 µm in-plane resolution. Tumors of both models exhibited similarly reduced stiffness compared to healthy tissue. However, through histo- logical analysis, softening in the glioblastoma model was attributed to vascularization and glycosaminoglycan content, while hemorrhaging explained softening in the melanoma model. By combining modalities, both the disease-induced biomechanical shift as well as its multiple causes were identified for each tumor model, showing the efficacy of the pro- tocol and motivating a large follow-up study. In a second study, high-resolution stiffness maps of wild-type and neuroblastoma beard- ing adult zebrafish were acquired for the first time. Using a significantly increased 60 × 60 µm in-plane resolution revealed regional stiffness variations in the brain as well as the biomechanical characteristics of the neuroblastoma tumors, whose location could also be matched to histology. In a third study, mouse aortas with induced abdominal aortic aneurysms were imaged ex vivo at a further increased resolution of 40 × 40 µm for the first time. This high resolution allowed spatial correlation of MRE-measured mechanical characteristics with histologi- cally determined protein concentrations, fulfilling the aim of the thesis. By effectively im- aging the remodeling of the extracellular matrix, this study also showed that MRE could serve as an urgently needed staging method for thrombus rupture risk. Taken together, these studies bridge the gap between elastography and the microscopic determinants of tissue mechanics, thereby significantly enhancing the explanatory power of the method. As an outlook, this work also presents a novel optical elastography method that was developed during this thesis. Based on the same concepts and processing pipe- lines used in MRE, it produced stiffness maps of zebrafish larvae and Bacillus subtilis biofilms at a resolution of 2 × 2 µm, further paving the way for histology-matched elas- tography.

Degree

thesis:*
Department dc:contributor.department
Charité - Universitätsmedizin Berlin
Year dc:date.issued
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Jordan, Jakob
Committee members dc:contributor.committeemember
  • N.N
  • N.N.

Subjects

dc:subject × 3

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • open access
Language dc:language
eng

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Freie Universität Berlin
Base URL
refubium.fu-berlin.de/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Jordan, Jakob. Microscopic Magnetic Resonance Elastography. 2026. https://doi.org/10.17169/refubium-50486