Freie Universität Berlin
Evaluation der Qualitätskontrolle der Maschinellen Autotransfusion
Abstract
dc:description.abstractBackground: The use of cell salvage makes it possible to reduce homologous blood transfusions during operations and avoid associated complications. Therefore, autotransfusion is an integral part of Patient Blood Management (PBM), which includes the avoidance of preoperative anaemia, an optimised surgical strategy and a rational use of blood products. The quality control of cell salvage is performed by checking the target values of a haematocrit in the autotransfusion blood (target: over 50%) and a total protein elimination (target: over 90%). The quality control data have not yet been comprehensively eval- uated at the Charité – Universitätsmedizin Berlin, which is therefore the subject of this monograph. Methods: This retrospective data analysis includes the use of the cell saver at the Charité Mitte Campus from 01.01.2019 to 01.03.2022 and at the Benjamin Franklin Campus from 01.01.2019 to 29.03.2022, in which autotransfusion occurred. In addition to the haematocrit and total protein elimination, the age and gender of the patients, as well as the surgical diagnosis, if available, were included to investigate possible factors influencing compliance with the target values. The data were analysed using SPSS. The medical cell salvage users were asked about possible reasons for deviations from the target values and acceptance criteria. Results: In total, a patient collective of 238 cell salvage applications (154 men, 84 women) was examined. The target values for quality control were achieved on average. The target value for haematocrit was not achieved in about 22% and for total protein elimination in about 8% of cell salvage applications. The age and sex of the patient, as well as the surgical diagnosis, have very little to no influence on compliance with the target values. The target values are not met primarily when the emergency programme of the cell saver is used, when the collection volume is too low, when the collection volume is heavily diluted with rinsing fluid or when the sample collection for quality control takes place in the first or last wash cycle. Conclusion: The target values for quality control were achieved in the majority of the cell salvage applications examined and are suitable for ensuring the quality of the autotransfusion. Special clinical constellations may lead to the treating anaesthetist having to accept deviating collection volumes or washing processes. Therefore, criteria for deviating quality control results should be defined in order to accept an undershooting of the target value for the haematocrit to be expected in the cell salvage procedure, e.g. in emergency situations, operations in children and low collection volumes, under PBM aspects and thus to justify the retransfusion of the salvaged blood in these cases. On the other hand, compliance with the target value for total protein elimination is to be demanded as a matter of principle; falling below this value is acceptable at best when emergency programmes are used.
Degree
thesis:*- Department dc:contributor.department
- Charité - Universitätsmedizin Berlin
- Year dc:date.issued
- 2026
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Dörffel, Debora
- Committee member dc:contributor.committeemember
-
- N.N.
Subjects
dc:subject × 4Rights
dc:rights.accessrights- Statement dc:rights.accessrights
-
- open access
- Licence dc:rights.uri
- Language dc:language
- ger
Identifiers
dc:identifier.*- URN
- urn:nbn:de:kobv:188-refubium-50901-9
- Identifier URI
- http://dx.doi.org/10.17169/refubium-50628