Back to search

Freie Universität Berlin

Der Einfluss des transvasalen Aortenklappenersatzes auf die rechtsventrikuläre und auf die linksventrikuläre Funktion

Abstract

dc:description.abstract

Background: Transcatheter aortic valve implantation (TAVI) is an innovative therapy for treating severe aortic valve stenosis (AS) in patients who, due to their risk profile, are not suitable for surgical aortic valve replacement (SAVR). The Euroscore II (ES II) is relevant for therapy selection. A diagnostic advantage in AS is provided by speckle-tracking echocardiography (STE) with strain deformation analysis, as it can detect myocardial damage earlier than conventional echocardiographic parameters and responds more sensitively to therapeutic interventions. Objective: This study examined left- and right-ventricular changes after TAVI using established parameters: ejection fraction (EF), tricuspid annular plane systolic excursion (TAPSE), and systolic pulmonary artery pressure (sPAP), as well as innovative parameters: left-ventricular (LV-GLS) and right-ventricular global longitudinal strain (RV-GLS), by echocardiography. In parallel, changes in functional status (New York Heart Association, NYHA class) were analyzed. Methods: Echocardiographic data and NYHA class of 123 TAVI patients were retrospectively evaluated. Examinations were performed before TAVI, at discharge, and after 6 months. The ES II was calculated for each patient. The influence of pre-interventional parameters (EF, ES II) on strain changes was also analyzed. Results: A significant improvement in the following parameters was observed after TAVI: sPAP normalized (before TAVI vs. at discharge vs. 6 months: 45.08 ± 15.65 vs. 39.24 ± 12.15 vs. 38.54 ± 11.36; p = 0.003), and RV-GLS improved (–17.75 ± 7.04 vs. –15.37 ± 5.71 vs. –19.07 ± 6.93; p = 0.015). The TAPSE course showed no significant change. For left-ventricular function, measured by EF and LV-GLS, a tendency toward improvement was observed, although without statistical significance. Functional status improved continuously (p < 0.001). LV-GLS was significantly influenced by EF (p = 0.017), in contrast to ES II. RV-GLS, however, showed a significant dependence on ES II (p = 0.012), while EF had no influence on right-ventricular strain. Conclusion: TAVI leads to a significant improvement in right-ventricular function, as reflected by sPAP and RV-GLS. TAPSE was not diagnostically useful in this regard. For left-ventricular function, no significant effect was observed; however, patients with low EF showed a greater improvement in LV-GLS. A high ES II was associated with an improvement in RV-GLS, whereas LV-GLS remained independent of ES II.

Degree

thesis:*
Department dc:contributor.department
Charité - Universitätsmedizin Berlin
Year dc:date.issued
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Kotseva, Bilyana
Committee member dc:contributor.committeemember
  • N.N.

Subjects

dc:subject × 3

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • open access
Language dc:language
ger

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Freie Universität Berlin
Base URL
refubium.fu-berlin.de/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Kotseva, Bilyana. Der Einfluss des transvasalen Aortenklappenersatzes auf die rechtsventrikuläre und auf die linksventrikuläre Funktion. 2026. https://doi.org/10.17169/refubium-51865