Freie Universität Berlin
Radiographic evaluation of crestal bone level changes around implants and abutment with non-corresponding diameters
Abstract
dc:description.abstractIntroduction: For the two-piece implant, the crestal bone levels have been described to be typically located approximately 1.5 to 2 mm below the implant- abutment junction (IAJ) at 1 year following implant restoration at the level the first thread of the two-piece implant. The term platform switching refers to the use of a smaller diameter abutment on a larger diameter implant collar. Some studies showed platform switching may help decrease the crestal bone loss but the results are still controversial. Materials and methods: This clinical radiologic evaluation retrospective study evaluated the peri-implant bone loss around two platform-switched implants (Bone-level implant and Wi.tal implant) with different implant-abutment connection designs with radiological examination over time. Result: In Wi.tal implant group, the mean crest bone loss were 1.16 mm (mesial) and 1.23 mm (distal) over time; in Bone-level implant group, the mean crestal bone loss was 0.73 mm (mesial) and 0.78 mm (distal) accordingly; the mesial (p=0.012) and distal (p=0.014) crestal bone loss was significantly different between Wi.tal and Bone-level implants. An increased vertical distance of the implant-abutment interface relative to the bone crest may reduce the amount of bone loss. Discussion: In this study, crestal bone loss increased when the implants were placed below the bone crest. It does seem important to keep the distance between the implant- abutment interface and the crestal bone surface. But between the Wi.tal implant group and Bone-level implant group, the horizontal distance from the implant-abutment interface to the edge of platform is the same (0.4 mm), supracrestal placement of Wi.tal implant shoulder did not prevent bone loss. The importance of the present study is the measurement of actual crestal bone loss around implant from the day of implant placement till the end of follow- up time. Most of platform-switching studies consider the distance between the shoulder of implant platform and bone-implant contact as crestal bone loss after follow up time, but without measuring the initial crestal bone height (bone above the platform shoulder or below the platform shoulder) on the day of implant placement. We assess the coronal bone loss at the implant platform during healing period, after abutment attachment and implant loaded. Conclusion: Platform-switching does not always reduce the amount of bone loss. It still needs further studies to clarify the factors influencing crestal bone changes at the implant shoulder.
Degree
thesis:*- Department dc:contributor.department
- Charité - Universitätsmedizin Berlin
- Year dc:date.issued
- 2016
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- He, Libo
- Committee member dc:contributor.committeemember
-
- N.N.
Subjects
dc:subject × 3Rights
dc:rights.accessrights- Statement dc:rights.accessrights
-
- open access
- Licence dc:rights.uri
- Language dc:language
- eng
Identifiers
dc:identifier.*- URN
- urn:nbn:de:kobv:188-fudissthesis000000102217-1
- Identifier URI
- http://dx.doi.org/10.17169/refubium-9724
- Dc Identifier Other
-
FUDISS_thesis_000000102217
FUDISS_derivate_000000019313