Freie Universität Berlin
Formulation development of biodegradable implants for extended parenteral delivery of protein drugs
Abstract
dc:description.abstractMaintenance of protein stability during formulation processing, storage and release is one of the main challenges for the effective parenteral delivery of protein drugs. Parenteral delivery with biodegradable injectable delivery systems based on poly(lactide-co-glycolide) (PLGA) has been successfully applied for the controlled delivery of low-molecular-weight drugs and peptides. This was, however, less successful for protein drugs due to their higher structural and functional complexity. Since proteins stability is generally better in the solid-state, hot-melt extrusion (HME) as a solvent- free process was evaluated for processing of protein formulations. Yet, the high processing temperatures and pressures in HME can be potential stress factors for protein stability. The purpose of this study was to assess the feasibility of hot-melt extrusion for preparing implants based on protein/PLGA formulations with special emphasis on protein stability, burst release and release completeness. Model protein (lysozyme)-loaded PLGA implants were prepared with a screw extruder and a self-built syringe-die device as a rapid screening tool for HME formulation optimization. Lysozyme stability was determined using DSC, FTIR, HPLC and biological activity. Lysozyme was recovered from implants with full biological activity after HME. The effect of hydration upon contact with the release medium (as a potential protein instability factor) on the recovery was studied by extraction of lysozyme from the implants after 1 day release. In spite of full recovery, functional stability was affected by the HME process conditions and its impact on the resulting matrix properties (e.g., porosity). Under optimized conditions, complete active recovery of the protein was obtained. The release from all implants reached the 100% value in 60–80 days with nearly complete enzymatic activity of the last fraction of released lysozyme. Pure PLGA implants with up to 20% lysozyme loading could be formulated without initial burst. To obtain optimized formulations with high drug loading and low burst release the simultaneous effect of lysozyme and PEG loadings on the initial release was investigated. This screening revealed that the effect of PEG is dependent not only on its size and concentration but also on the concentration of the protein. At drug loadings exceeding 20%, incorporation of PEG 400 reduced the initial burst. Accordingly, a complete lysozyme recovery in active form with a burst-free and complete release from PLGA implants prepared by hot-melt extrusion was obtained. This is in contrast to several reported microparticulate lysozyme-PLGA systems and suggests the great potential of hot-melt extrusion for the preparation of protein-PLGA implants. The conformational stability during HME process was further examined with three less stable proteins; ovalbumin, cytochrome C and bovine serum albumin (BSA). DSC and FTIR revealed stability of the proteins and absence of non-covalent aggregation. This was especially interesting in the case of BSA which is a large and multi domain protein and highly prone to aggregation. MALDI-MS analysis revealed no detectable impurity formation after the process. BSA however, presented more challenges during release; high initial burst and incomplete release. The initial burst release was reduced by milling the protein prior to extrusion. Thus, PLGA implants with up to 25% BSA loading could be formulated without initial burst. The cumulative release was incomplete at 70% at loadings below the percolation threshold of the protein, while higher protein loadings increased the release to 97%. However, in all cases, an insoluble implant mass remained for over 6 months. Analysis of the residual matrices suggested a covalent linkage of BSA to PLGA oligomers via thioester bonds. Thus, covalent protein-PLGA adducts were responsible for the incomplete release from the delivery systems containing BSA. Increasing the porosity of the implants using ethanol-containing PLGA resulted in 100% release at 90 days with no insoluble implant mass remaining. Nevertheless, the presence of PLGA in the insoluble implant mass was surprising because in the absence of proteins PLGA degraded completely into water-soluble oligomers within 50-60 days. BSA reduced the PLGA degradation and erosion rate and most importantly the extent of the erosion. The total releasable protein fraction was correlated with the extent of PLGA mass-loss. Release study of implants prepared with pre-degraded PLGA exhibited similar BSA release pattern and completeness. This suggested that the degradation phase was not responsible for release incompleteness. Thus, to achieve complete release, enhancement of out-flux of degradation products, through an increase in porosity during the erosion phase, was intended. The porosity could be a result of higher diffusional release e.g. by reduction of matrix size or increasing BSA loading above its percolation threshold. Addition of pore-formers and/or plasticizers also increased both diffusional and erosional release. Consequently, no residual implants remained after complete release of BSA. Accordingly, enhancement of out-flux of PLGA degradation products, once formed, was proposed to increase protein-release completeness. In conclusion, hot-melt extrusion as a solvent-free process provided better stability of proteins and hence is a promising technique for processing of biodegradable implants for delivery of protein drugs.
Degree
thesis:*- Department dc:contributor.department
- Biologie, Chemie, Pharmazie
- Year dc:date.issued
- 2011
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Ghalanbor, Zahra
- Committee members dc:contributor.committeemember
-
- Prof. Dr. Roland Bodmeier
- Prof. Dr. Philippe Maincent
Subjects
dc:subject × 6Rights
dc:rights.accessrights- Statement dc:rights.accessrights
-
- open access
- Licence dc:rights.uri
- Language dc:language
- eng
Identifiers
dc:identifier.*- URN
- urn:nbn:de:kobv:188-fudissthesis000000022207-0
- Identifier URI
- http://dx.doi.org/10.17169/refubium-10100
- Dc Identifier Other
-
FUDISS_thesis_000000022207
FUDISS_derivate_000000009313