Freie Universität Berlin
Models for Percutaneous Absorption – Influential Parameters and in silico Predictions
Abstract
dc:description.abstractDermal absorption – the uptake of compounds via the skin – is a relevant parameter for risk assessment of chemicals, cosmetics and plant protection products. Besides in vivo tests, in vitro determination is accepted by many regulatory agencies – if experiments are conducted in accordance to OECD Guideline 428 and Guidance document 28. However, the named documents provide a framework whereupon variability regarding performance and results may be observed in different laboratories. A way to minimize variability is to understand the influence of experimental conditions and higher standardization of the system. Regarding the latter, the Guideline requests an integrity test which should ensure the exclusive use of undamaged skin preparations. Proposed tests are TEWL (transepidermal water loss), TEER (transepidermal electrical resistance), application of a reference compound like water (TWF, transepidermal water flux) or the integrated use of an internal standard (ISTD). However, contradictory opinions concerning applicability, experimental performances and limit values have been reported. To evaluate the suitability of different tests and review the present limit values, absorption results of four 14C-labeled test compounds (MCPA (2-methyl-4-chlorophenoxyacetic acid), MCPA-EHE (MCPA 2-ethylhexylester), testosterone and caffeine) were compared with results of five integrity tests: TEWL, TWF, TEER in advance, ISTD (3H- mannitol, 3H-caffeine, or 3H-testosterone) concurrently and BLUE (transepidermal methylene blue absorption) at the end of the run. The standard methods TEWL, TWF and TEER were assessed to be appropriate tools for rough differentiation between intact and impaired skin samples in advance of experiments, when using limit values 10 g/(m²*h), 4.5*10-3 cm/h and 2 kOhm, respectively. However, only the absorption characteristics of a parallelly applied ISTD were highly correlated with absorption results of the 14C-labeled test compound (e.g. R² 0.86 for maxKp (maximum permeability coefficient) 14C- MCPA and 3H-testosterone). Further advantages of the ISTD approach are the possibility to rate the barrier function over the entire experimental period and to distinguish substance-specific wash-in effects from barrier-disruption related effects. The independence of 3H-ISTD and 14C-test compound analytics as well as the independence of their absorption characteristics were shown in the current work. An obstacle for routine application is the need of historical datasets for various ISTDs – representative for various physicochemical properties – applied under various experimental conditions. Regarding investigation of possible influential experimental parameters, the use of flow-through and static study design was compared. Therefore, 14C-MCPA and 3H-testosterone were applied on dermatomed rat skin semi-occlusively with water as the receptor fluid. In accordance with the literature, similar absorption results were obtained with the two experimental designs, e.g. maxKp values for 14C-MCPA of 21.4 ± 10.4*10-5cm/h under static and 22.8 ±18.4*10-5cm/h under flow-through conditions. Repeated application of a formulation containing the pesticide MCPA over three days in advance to the application of the corresponding radio-labeled formulation on rat skin led to a significant increase of the absorption (AD 75 ± 24 %) compared to the standard experiments with a single application of 14C-MCPA (14 ± 3 %). This effect was only partly due to the formulation, but also due to mechanical and chemical stress during washing procedures between the applications. It was observed that the skin became less resistant to mechanical treatment with increasing time. Therefore, the study design with repeated dosing in vitro was assessed as not feasible for routine applications. Furthermore, absorption characteristics of dermatomed (DMS) and full-thickness (FTS) skin samples derived from the same human donor were compared under identical experimental conditions. Absorption results for four 14C-labeled (MCPA-EHE, MCPA, testosterone and caffeine) and two 3H-labeled (testosterone and mannitol) penetrants under finite dose conditions were in the same order of magnitude for both preparation types (e.g. 3H-testosterone, absorbed dose (AD) 22.1 ± 7.1 % for DMS and 25.6 ± 9.2 % for FTS). However, DMS was assessed to be more suitable for routine studies due to Kp values closer to the steady state situation. Since the availability of human skin is limited, rat skin, StrataTest® (a commercially available reconstructed human skin) and skin-PAMPA (an abiotic stratum corneum membrane) were assessed for their suitability to determine dermal absorption. Therefore, experiments were conducted with 14C- labeled and unlabeled model compounds (testosterone, caffeine and MCPA) under similar experimental conditions. In accordance with the literature, rat skin was assessed to be an appropriate alternative to human skin due to absorption results in the same order of magnitude and fulfilling the regulatory principle of ‘worst case’ for purposes of risk assessment (e.g. for pesticides). Skin- PAMPA was highly over-predictive in comparison to human skin ((max)Kp 3- to 53-fold). If focusing on aqueous solutions skin-PAMPA was less over-predictive ((max)Kp 3- to 8-fold) and the results were correlated to human skin results (R2 0.89). However, further tests are needed to assess its usability for other vehicles – which would be crucial for its application as screening tool during pesticide development. In contrast, formulations could be applied on the cell- based construct StrataTest®. However, the system was highly over-predictive in comparison to human skin (maxKp 5- to 49-fold, AD 3- to 4-fold), not correlated to human in vitro experiments and therefore assessed as inappropriate to determine dermal absorption. Besides the absorption, also xenobiotic-metabolizing enzyme activities were investigated for StrataTest® using subcellular fractions. Remarkable esterase and NAT 1 activities were detected in S9 fraction (3.6 ± 0.1 and 7.2 ±1.6 nmol/(min*mg), respectively). But lacking UGT 1 and ADH activity and providing low AlDH and FMO 1/3 activities (3.1 ± 0.8 and 0.5 ± 0.1 nmol/(min*mg), respectively) – measured in microsomes or cytosol – StrataTest® was closer to a keratinocyte cell line than to the metabolic properties of excised human skin, reconstructed human epidermis (EpiDermTM) or other full-thickness skin constructs (EpiDermTMFT and Phenion®FT). Additionally, cryoconserved human skin (-20°C, up to 1 year) was examined for preserved esterase activity. Using S9 fraction and model substrates MCPA-EHE and fluorescein diacetate resulted in activities of 0.67 ± 0.26 nmol/(mg*min) and 0.7 ± 0.6 nmol/(min*mg), respectively. Furthermore, model compound MCPA-EHE was partially cleaved to MCPA during dermal absorption experiments in vitro. It was concluded, that a change of absorption characteristic due to metabolic hydrolysis and changed physicochemical properties is covered qualitatively when using cryoconserved human skin. However, considering the hints of enzyme degradation during storage, a considerably lower extent is likely. Finally, in silico prediction models for dermal absorption with special focus on mixture-related effects were developed. Data from more than 342 dermal absorption experiments in vitro were used, which comprised 56 test compounds in more than 100 formulations. A model based on one substance-specific Abraham descriptor (Rf2, solute excess molar refractivity), a mixture-specific factor (TPSA, topological polar surface area) and a species indicator (SpI) was assessed to be appropriate to estimate the magnitude of permeation of compound-mixture combinations and therefore to be a suitable screening tool for early stages of development (e.g. for pesticides). More precise predictions were possible with the substance-based approach where substance-related information were bundled in class variables and combined with mixture factors (molinspLogHBAcc, logarithmic number of hydrogen bond acceptors, Adme1/Pow, inverse octanol/water partition coefficient, Adme1/RotB, inverse number of rotatable bonds). This model allows reliable interpolations for included test substances to novel formulations. Taken together, the current work supplements current knowledge about the in vitro methodology as well as the in silico predictions for dermal absorption. However, further improvements are needed to enhance the reproducibility of the former and allow the routine application of the latter.
Degree
thesis:*- Department dc:contributor.department
- Biologie, Chemie, Pharmazie
- Year dc:date.issued
- 2013
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Guth, Katharina
- Committee members dc:contributor.committeemember
-
- Prof. Dr. Monika Schäfer-Korting
- Prof. Dr. Gerhard Wolber
Subjects
dc:subject × 4Rights
dc:rights.accessrights- Statement dc:rights.accessrights
-
- open access
- Licence dc:rights.uri
- Language dc:language
- eng
Identifiers
dc:identifier.*- URN
- urn:nbn:de:kobv:188-fudissthesis000000094743-4
- Identifier URI
- http://dx.doi.org/10.17169/refubium-10330
- Dc Identifier Other
-
FUDISS_thesis_000000094743
FUDISS_derivate_000000013758