Freie Universität Berlin
Measuring fluid shear stress with a novel Doppler-derived relative pulse slope index and maximal systolic acceleration approach to detect peripheral arterial disease and to modulate arteriogenesis
Abstract
dc:description.abstractGenerally, the severity of PAD is monitored over time by the ankle-brachial index (ABI); however, the disease progression of PAD in diabetic individuals is often underestimated due to frequent medial vascular calcification (VCm). To improve the diagnostic precision of PAD for diabetic patients, two novel Doppler measurements that assess peripheral blood flow were investigated: the maximal systolic acceleration (ACCmax) and relative pulse slope index (RPSI). The feasibility of these non-invasive approaches was validated in a prospective clinical trial using a novel algorithm called ‘Gefäßtachometer’. 1) Specifically, ACCmax and RPSI were evaluated in 168 patients (310 arteries measured), including 91 non-diabetic and 77 diabetic patients. The optimal threshold of ACCmax was calculated to be 444 cm/s2 in the diabetic population, with a positive predictive value (PPV) of 96% and a negative predictive value (NPV) of 72%. The optimal threshold of RPSI was calculated to be 74 s-1 in diabetic populations, with a PPV of 91% and an NPV of 71%. Compared to the ABI measurements, the diagnostic PPVs increased by 22% using ACCmax and by 17% using RPSI. A logistic regression and a parallel test were conducted, which further increased the diagnostic specificity to 95% in the diabetic population. 2) Twenty-five PAD patients were enrolled one day before revascularisation, and 44 tibial arteries were measured one day before revascularisation and directly after revascularisation. The ACCmax increased from 427.83 ± 171.67 cm/s2 to 509.30 ± 171.23 cm/s2 (P = 0.002); the RPSI decreased from 82.17 ± 58.76 s-1 to 64.08 ± 39.65 s-1 (P = 0.022). 3) Moreover, a dynamic change of ACCmax and RPSI under different ECP treatment pressures was observed in 18 healthy volunteers. The ECP device, composed of electrocardiographic-triggered compressions of the lower extremities, has been widely applied for refractory angina pectoris. With an increase of ECP pressure from 0 to 200 mmHg, the haemodynamics of the participants responded differently on an individual basis to the increase of ECP pressure, and the maximal amplitude of diastolic ACCmax was approximately 200%. In summary, the RPSI and ACCmax measurements provided a more predictive diagnosis than ABI for estimating the PAD status in diabetic patients. The digital translation of Doppler signals and the computer-assisted calculation of haemodynamics served as essential technical foundations for future computer-aided PAD diagnoses. These data may guide post-revascularisation surveillance and may allow for optimised and novel individual ECP treatments.
Degree
thesis:*- Department dc:contributor.department
- Charité - Universitätsmedizin Berlin
- Year dc:date.issued
- 2017
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Li, Lulu
- Committee member dc:contributor.committeemember
-
- N.N.
Subjects
dc:subject × 4Rights
dc:rights.accessrights- Statement dc:rights.accessrights
-
- open access
- Licence dc:rights.uri
- Language dc:language
- eng
Identifiers
dc:identifier.*- URN
- urn:nbn:de:kobv:188-fudissthesis000000104253-6
- Identifier URI
- http://dx.doi.org/10.17169/refubium-4837
- Dc Identifier Other
-
FUDISS_thesis_000000104253
FUDISS_derivate_000000021094