Back to search

Freie Universität Berlin

Evaluation of automated and manual perfusion MRI post-processing

Abstract

dc:description.abstract

In perfusion magnetic resonance imaging a manual approach to delineation of regions of interest is, due to rater bias and time intensive operator input, clinically less favorable than an automated approach would be. We have compared the performances of these approaches, testing the hypothesis that automated protocols suffer from numerous artifacts which result in a false estimation of hypoperfused tissue. An additional goal of our study was to find a minimally biased yet maximally useful perfusion post‐processing protocol which could offer the treating physician an estimate of tissue fate. Methods One hundred and eighty‐four patients were included in this study, of which 39 control patients with neither a fresh infarction visible nor a final diagnosis of stroke and 145 patients with a confirmed diagnosis of acute ischemic stroke. Using three different software packages (Perfscape/Neuroscape, PMA and Stroketool) maps of mean transit time (MTT), cerebral blood flow (CBF) and Tmax were created. Three different thresholds were applied on each parameter map and subsequent volumes of hypoperfused tissue were calculated using both a manual and an automated protocol. Results The median difference between the automatically and manually derived volumes was up to 210 ml in Perfscape/Neuroscape, 123 ml in PMA and 135 ml in Stroketool. Correlation coefficients between perfusion volumes and radiological and clinical outcome were much lower for the automatic volumes than for the manually derived ones. Using the manual approach in patients with a persistent vessel occlusion a CBF map with a restrictive threshold had shown volumes of tissue at definite risk of infarction in up to a 100% of patients. The additional use of a CBF map with a high threshold had enabled identification of patients without penumbra. Conclusions The agreement of the automated and manual method was very poor, with the automated use producing falsely exaggerated volumes of hypoperfused tissue. No one combination of software, map and threshold was able to give a reliable estimate of tissue fate. However in patients with a vessel occlusion, a combination of a CBF map with a low threshold and a high threshold can provide a calculation of the minimum volume of brain tissue inevitably to be lost if the occlusion persists.

Degree

thesis:*
Department dc:contributor.department
Charité - Universitätsmedizin Berlin
Year dc:date.issued
2013

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Galinovic, Ivana
Committee members dc:contributor.committeemember
  • PD Dr. med. Jochen B. Fiebach
  • PD Dr. med. Götz Thomalla
  • Prof. Dr. Vincent Thijs

Subjects

dc:subject × 3

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • open access
Language dc:language
eng

Identifiers

dc:identifier.*
URN
urn:nbn:de:kobv:188-fudissthesis000000040372-3
Dc Identifier Other
FUDISS_thesis_000000040372
FUDISS_derivate_000000012707

Chain of custody

source
Harvested from
Freie Universität Berlin
Base URL
refubium.fu-berlin.de/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Galinovic, Ivana. Evaluation of automated and manual perfusion MRI post-processing. 2013. https://refubium.fu-berlin.de/handle/fub188/7784