Freie Universität Berlin
Direct labeling rolling circle amplification for straightforward signal increase in biodetection formats based on fluorescence spectroscopy studies
Abstract
dc:description.abstractThe goal of this work was to develop a direct labeling rolling circle amplification (RCA)-based detection protocol as a straightforward and preferable general amplification strategy applicable to various detection platforms. To this end an alternative fluorophore label to Cy3, the most commonly used green excitation dye in biodetection formats, were sought. The most suitable dye, DY-555, was employed in microarray assays yielding a protocol that reduces handling and reaction time efficiently with lesser costs while providing a great signal yield. Seven fluorophores from different dye classes were investigated with steady-state and time-resolved spectroscopy to identify a candidate yielding maximum fluorescence with a minimum amount of dye molecules in a DNA template with defined labeling site spacing for the enzymatic integration of the dye-dUTPs. The most favorable properties were: High fluorescence quantum yield, absorption/emission features with a minimum sensitivity to the dye's microenvironment, and good photochemical stability. For future for multiplexed real-time detection a fluorescence lifetime well above the signal for the scattered excitation light for potential detection with time-resolved fluorescence would be favorable. DY-555 offered all of these properties along with lesser cost than Cy3 and was subsequently chosen as the fluorophore label for assay studies. An enzymatic direct labeling protocol for RCA-based signal amplification on a DNA microarray via dye-dUTPs was established. Next to the fluorophores, the labeling strategy, composition of reaction solution, and number of handling steps where optimized. With the resulting protocol, the assay's runtime and handling steps could be reduced while increasing the signal yield. The procedure was also carried out on an antibody microarray portraying the feasibility of applying this protocol to other RCA-based platforms. These features are very attractive for many detection formats but especially for point-of-care diagnostic kits that need to be easy enough to be performed by scientifically untrained personnel.
Degree
thesis:*- Department dc:contributor.department
- Biologie, Chemie, Pharmazie
- Year dc:date.issued
- 2012
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Linck, Lena
- Committee members dc:contributor.committeemember
-
- Prof. Dr. Volker A. Erdmann
- Prof. Dr. Burghardt Wittig
Subjects
dc:subject × 8Rights
dc:rights.accessrights- Statement dc:rights.accessrights
-
- open access
- Licence dc:rights.uri
- Language dc:language
- eng
Identifiers
dc:identifier.*- URN
- urn:nbn:de:kobv:188-fudissthesis000000037671-6
- Identifier URI
- http://dx.doi.org/10.17169/refubium-12259
- Dc Identifier Other
-
FUDISS_thesis_000000037671
FUDISS_derivate_000000011147