Back to search

Freie Universität Berlin

Evaluation of multi-parametric Magnetic Resonance Imaging for the detection of prostate cancer

Abstract

dc:description.abstract

Objective: To evaluate multiparametric Magnetic Resonance Imaging (MP-MRI), including proton magnetic resonance spectroscopy (1H-MRS), diffusion-weighted MRI (DW-MRI), and dynamic-contrast enhanced MRI (DCE-MRI) for the detection of prostate cancer (PCa), and in prostate biopsy and risk estimation of PCa recurrence called biochemical recurrence (BCR). Material and Methods: Institutional review board approval and informed consent were obtained in all studies. In the first study ex vivo intact-tissue spectroscopy at 14 T was used to estimate the risk of PCa recurrence after prostate surgery from 48 individual patients. Further in the second study MRI-guided prostate biopsy was performed on 54 patients and diagnostic parameters were calculated for all combinations of T2-weighted imaging with MP-MRI. The third study compared detection rates for PCa from 32 patients with indication for a systematic re- biopsy. These patients underwent 3 T MP-MRI without endorectal coil and subsequent targeted biopsies were performed in MRI/Ultrasound (US) fusion mode followed by a systematic standard transrectal ultrasound (TRUS) guided biopsy. Results: In the first study principal component analysis (PCA) was performed on all spectral regions from cases of clinical stage-matched groups with and without recurrence and four pathology-related principal components were identified. Canonical analysis defined metabolomic profiles as the canonical score that could differentiate the BCR from non-BCR with statistical significance. By applying the coefficients from PCA and canonical analysis to the pathologicalstage-matched groups, recurrence was predicted with an accuracy of 78 %. In the second study, in 54 consecutive patients biopsy was performed in 178 lesions; 53 were positive for prostate cancer. Detection rates and test negative results, respectively, were as follows: T2-weighted imaging, 70 % and 50 %; T2-weighted imaging and 1H-MRS, 81 % and 32 %; T2-weighted imaging and DCE-MRI, 83 % and 29 %; T2-weighted imaging and DWI, 85 % and 30 %; T2-weighted imaging, 1H-MRS, and DCE-MRI, 91 % and 13 %; T2-weighted imaging, 1H-MRS, and DWI, 94 % and 15 %; T2-weighted imaging, DWI, and DCE-MRI, 94 % and 13 %; T2-weighted imaging, 1H-MRS, DWI, and DCE-MRI, 100 % and 0 %. In the third study, the proportional portion of histologically confirmed cancers in the study group (n = 32) of the MRI/US fusion biopsy (11/12; 34.4 %) was in comparison to the TRUS guided systematic biopsy (6/12; 18.8 %) significantly higher (p = 0.01). Conclusion: MP-MRI showed its substantial contribution to the detection of prostate cancer, the improvement of prostate biopsy and its potential to predict PCa biochemical recurrence. With further studies, this may greatly contribute to the future design of clinical strategy for personalized treatment of PCa patients.

Degree

thesis:*
Department dc:contributor.department
Charité - Universitätsmedizin Berlin
Year dc:date.issued
2014

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Maxeiner, Andreas
Committee member dc:contributor.committeemember
  • N.N.

Subjects

dc:subject × 3

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • open access
Language dc:language
eng

Identifiers

dc:identifier.*
URN
urn:nbn:de:kobv:188-fudissthesis000000097042-4
Dc Identifier Other
FUDISS_thesis_000000097042
FUDISS_derivate_000000015449

Chain of custody

source
Harvested from
Freie Universität Berlin
Base URL
refubium.fu-berlin.de/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Maxeiner, Andreas. Evaluation of multi-parametric Magnetic Resonance Imaging for the detection of prostate cancer. 2014. https://refubium.fu-berlin.de/handle/fub188/8267