Back to search

Freie Universität Berlin

The apply of spectral domain optical coherence tomography in retinal vessel assessment of diabetic retinopathy

Abstract

dc:description.abstract

Purpose: To evaluate spectral domain optical coherence tomography (SD-OCT) based methods to differentiate retinal vessel types and easure retinal vessel diameters, and compare these findings with the reference from infrared reflectance (IR) images and/or fluorescein angiography (FA); then, evaluate the retinal vessel diameters in relation to different severity grades of diabetic retinopathy using SD-OCT. Methods: Patients who underwent circular OCT-scans centered at the optic disc with or without non-proliferative diabetic retinopathy (NPDR) were retrospectively reviewed. Individual retinal vessels were identified on IR and given unique labels both on IR and SD-OCT. Vessel types (artery, vein or uncertain) and vessel width obtained by IR and/or FA were documented as ground truth. From OCT, presence of the hyperreflective lower border reflectivity feature and measurements of each vessel, including horizontal vessel contour diameter, vertical vessel contour diameter, horizontal hyperreflective core diameter, and reflectance shadowing width, were assessed. Results: A total of 398 vessels with documented vessel type were included for vessel type assessment. Using SD-OCT, 338 vessels were assigned a final grade, of which, 86.4% (292 vessels) were classified correctly. When using only IR based ground truth for vessel type, the SD-OCT based classification approach reached a sensitivity of 0.88/0.93, and a specificity of 0.93/0.88 for arteries/veins, respectively. 194 vessels larger than 40 μm were documented for diameter measurements. The mean vessel width obtained from IR was 107.9±36.1 μm. A mean vertical vessel contour diameter of 119.6±29.9 μm and a mean horizontal vessel contour diameter of 124.1±31.1 μm were measured by SD-OCT. Vertical vessel contour diameter did not differ from vessel width in all subgroup analysis. Horizontal vessel contour diameter was not significantly different from vessel width for arteries and had strong (r=0.88m) or very strong (r=0.91) correlation with vessel width for veins. Of 59 eyes from 45 patients examined, 30 (50.2%) had mild NPDR and 29 (49.8%) had severe NPDR, respectively. Eyes with mild NPDR had wider mean arteriolar vertical vessel inner diameter (89.8±12.1μm), vertical vessel outer diameter (120.9±12.9μm), and vessel shadow width (81.3±15.3μm) than patients with severe NPDR (87.9±10.8μm, 119.1±9.7μm, 78.8±10.9μm). However, the differences were not statistically significant (p=0.53, 0.55, 0.47). In contrast, wider venular diameters were associated with increasing severity of NPDR (p=<0.001, <0.001, 0.007). Conclusion: Retinal vessel type assessment and diameter measurements can be achieved with the current generation of SD-OCTs and be routinely implemented in the clinic. Wider retinal venule diameter was significantly associated with the severity of NPDR by SD-OCT assisted measurement.

Degree

thesis:*
Department dc:contributor.department
Charité - Universitätsmedizin Berlin
Year dc:date.issued
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Shao, Qing
Committee member dc:contributor.committeemember
  • N.N.

Subjects

dc:subject × 3

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • open access
Language dc:language
eng

Identifiers

dc:identifier.*
URN
urn:nbn:de:kobv:188-fudissthesis000000103016-4
Dc Identifier Other
FUDISS_thesis_000000103016
FUDISS_derivate_000000020015

Chain of custody

source
Harvested from
Freie Universität Berlin
Base URL
refubium.fu-berlin.de/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Shao, Qing. The apply of spectral domain optical coherence tomography in retinal vessel assessment of diabetic retinopathy. 2016. https://refubium.fu-berlin.de/handle/fub188/9232