Back to search

Freie Universität Berlin

Beam Diagnostics and Spectroscopy at X-ray Free Electron Lasers

Abstract

dc:description.abstract

The demands to the FEL X-ray optics are extremely high. They must be able to preserve the properties of the new sources as good as possible; speaking not only of the enormous photon density per time, but also of coherence and extremely low divergence, generated by the FELs. This occurs at pulse repetition rates in the range of up to several kHz. Such high-energy pulses in the GW range pose the question of whether the used optics is able to withstand these conditions (for a longer time). Possible applications and limitations of modern optics such as reflection zone plates are investigated and demonstrated here. The present work involves both simulation and experimental tests. It is divided into four sub-projects. Each one describes the different states of the FEL. The first sub-project with the European XFEL GmbH in Hamburg includes the commissioning of the FEL. Here, two different methods for the precise adjustment of the undulator segments of the long FEL undulators (200 m) are presented, by measuring the so-called K-parameter, magnet field strength in the undulator, the product of magnet field and period length of a magnetic structure. For that, a 2- or 4-crystal monochromator is used, which is able to determine the K-parameters with an accuracy of 10-4 to 10-6. The proposed methods were successfully demonstrated using undulator radiation at the PETRA III facility. The second sub-project with European XFEL is dedicated to the measurement of the spectral parameters of the actual resulting FEL radiation from pulse to pulse, single-shot spectroscopy. For this purpose, various methods have been investigated that can register the spectral response with sufficiently high precision. It was thereby demonstrated that resolutions down to 3.2 meV at the pulse energy of 10 keV are feasible. In a third project, with LBNL in Berkeley and at LCLS in Stanford, a new spectroscopic setup was implemented, which is able to detect the fluorescence spectra from highly diluted elements under interaction of FEL X-ray pulses with a liquid jet in vacuum. The signals, previously not measurable due to low intensity in the complex context of photosynthesis spectroscopy were observed. The system development and a successful improvement are presented. The fourth project describes an X-ray transport line coupled with a spectrometer for conducting cross-dispersive resonant inelastic X-ray spectroscopy (RIXS) experiments. This is theoretically examined as a case-study. With this apparatus it is possible to achieve an energy resolution of E/DE ≈ 30,000 in the soft X-ray regime (776 eV as an example) at simultaneous recording of the absorbed and emitted radiation, which will enable a new class of fundamental research using RIXS experimental studies.

Degree

thesis:*
Department dc:contributor.department
Physik
Year dc:date.issued
2014

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Rehanek, Jens Konstantin
Committee members dc:contributor.committeemember
  • Professor Dr. Alexei Erko
  • Professor Dr. Holger Dau

Subjects

dc:subject × 5

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • open access
Language dc:language
eng

Identifiers

dc:identifier.*
URN
urn:nbn:de:kobv:188-fudissthesis000000096954-5
Dc Identifier Other
FUDISS_thesis_000000096954
FUDISS_derivate_000000015395

Chain of custody

source
Harvested from
Freie Universität Berlin
Base URL
refubium.fu-berlin.de/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Rehanek, Jens Konstantin. Beam Diagnostics and Spectroscopy at X-ray Free Electron Lasers. 2014. https://refubium.fu-berlin.de/handle/fub188/9969