Back to search

Georgia Institute of Technology

Development and Test of a GEM-Based TEPC for Neutron Protection Dosimetry

Abstract

dc:description.abstract

The effective dose equivalent, H (or the effective dose, E ) to an individual is the primary limiting quantity in radiation protection. However, techniques for measuring H for neutrons have not been fully developed. In this regard a new tissue equivalent proportional counter (TEPC) based on a gas electron multiplier (GEM) for measuring H*(10), which is a conservative estimate of H, for neutrons was designed and constructed. The deposited energy distribution for two different neutron sources (a Cf-252 source and a AmBe source) was measured using the new TEPC. The measurements were performed using two different proportional gases: P-10 gas and a propane-based tissue equivalent gas at various pressures. A computer simulation of the new TEPC, based on the Monte Carlo method, was performed in order to obtain the pulse height distributions for the two neutron sources. The simulated results and the measured results were compared. Results show that the experimental results agree with the computational results within 20% of accuracy for both Cf-252 and AmBe neutron sources. A new model GEM-based TEPC was developed for use in obtaining H*(10). The value of H*(10) for the Cf-252 source and for the AmBe source using experimental measurements was obtained. These results are presented in this study. The study shows that the GEM-based TEPC can successfully estimate H*(10). With these results and some refinements, this GEM-based TEPC can directly be used as a neutron rem meter.

Degree

thesis:*
Department dc:contributor.department
Mechanical Engineering
Grantor dc:publisher
Georgia Institute of Technology
Year dc:date.issued
2007

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Seydaliev, Marat Radikovich
Advisor dc:contributor.advisor
  • Wang, C.-K. Chris
Committee members dc:contributor.committeemember
  • Wood, John
  • De Oliveira, Cassiano
  • Fox, Tim
  • Hertel, Nolan

Subjects

dc:subject × 9

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1853/14607

Chain of custody

source
Harvested from
Georgia Tech
Base URL
repository.gatech.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Seydaliev, Marat Radikovich. Development and Test of a GEM-Based TEPC for Neutron Protection Dosimetry. Georgia Institute of Technology, 2007. http://hdl.handle.net/1853/14607