Back to search

Georgia Institute of Technology

Dynamic thermal response of the data center to cooling loss during facility power failure

Abstract

dc:description.abstract

Provisioning for power failure is an important element of data center design. It is important to assess both tangible and intangible costs of unplanned data center downtime. These costs must be compared with the capital cost of providing various levels of backup power infrastructure to compute and cooling equipment. Various levels of backup power infrastructure each lead to a most probable transient scenario after utility power failure. Because of differences between facilities, the level of risk that unacceptable compute equipment inlet temperature associated with each level of backup power infrastructure is not standardized; in particular, facilities with differing compute equipment power densities may require different levels of backup power infrastructure to maintain safe operation. Choosing one level of backup power infrastructure above another is not necessarily obvious for every facility, as there may be large gaps in costs and unknown levels of risk for lower levels of provisioning. A first order model is also used to compare inclusion of various thermal capacitance values with experimental results. Room level experiments also illustrate the relative level of risk associated with various levels of provisioning for the same control volume and compute equipment. Although provisioning to back up as much equipment as possible remains the "safest" solution, cost will continue to play a factor in facility design decisions. This work offers a step toward appropriate modeling of data center power failure events and suggests further steps to continue the process.

Degree

thesis:*
Department dc:contributor.department
Mechanical Engineering
Grantor dc:publisher
Georgia Institute of Technology
Year dc:date.issued
2009

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Shields, Shawn
Advisor dc:contributor.advisor
  • Joshi, Yogendra
Committee members dc:contributor.committeemember
  • Mostafa Ghiaasiaan
  • Jeter, Sheldon M.

Subjects

dc:subject × 19

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1853/29725

Chain of custody

source
Harvested from
Georgia Tech
Base URL
repository.gatech.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Shields, Shawn. Dynamic thermal response of the data center to cooling loss during facility power failure. Georgia Institute of Technology, 2009. http://hdl.handle.net/1853/29725