Reduced-data magnetic resonance imaging reconstruction methods: constraints and solutions.

Abstract

dc:description.abstract

Imaging speed is very important in magnetic resonance imaging (MRI), especially in dynamic cardiac applications, which involve respiratory motion and heart motion. With the introduction of reduced-data MR imaging methods, increasing acquisition speed has become possible without requiring a higher gradient system. But these reduced-data imaging methods carry a price for higher imaging speed. This may be a signal-to-noise ratio (SNR) penalty, reduced resolution, or a combination of both. Many methods sacrifice edge information in favor of SNR gain, which is not preferable for applications which require accurate detection of myocardial boundaries. The central goal of this thesis is to develop novel reduced-data imaging methods to improve reconstructed image performance. This thesis presents a novel reduced-data imaging method, PINOT (Parallel Imaging and NOquist in Tandem), to accelerate MR imaging. As illustrated by a variety of computer simulated and real cardiac MRI data experiments, PINOT preserves the edge details, with flexibility of improving SNR by regularization. Another contribution is to exploit the data redundancy from parallel imaging, rFOV and partial Fourier methods. A Gerchberg Reduced Iterative System (GRIS), implemented with the Gerchberg-Papoulis (GP) iterative algorithm is introduced. Under the GRIS, which utilizes a temporal band-limitation constraint in the image reconstruction, a variant of Noquist called iterative implementation iNoquist (iterative Noquist) is proposed. Utilizing a different source of prior information, first combining iNoquist and Partial Fourier technique (phase-constrained iNoquist) and further integrating with parallel imaging methods (PINOT-GRIS) are presented to achieve additional acceleration gains.

Degree

thesis:*
Department dc:contributor.department
Electrical and Computer Engineering
Grantor dc:publisher
Georgia Institute of Technology
Year dc:date.issued
2011

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Hamilton, Lei Hou
Advisor dc:contributor.advisor
  • Brummer, Marijn E.
Committee members dc:contributor.committeemember
  • John Oshinski
  • Justin Romberg
  • Shella Keilholz
  • Xiaoli Ma
  • Xiaoping Hu

Subjects

dc:subject × 11

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1853/42707

Chain of custody

source
Harvested from
Georgia Tech
Base URL
repository.gatech.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Hamilton, Lei Hou. Reduced-data magnetic resonance imaging reconstruction methods: constraints and solutions.. Georgia Institute of Technology, 2011. http://hdl.handle.net/1853/42707