Back to search

Georgia Institute of Technology

Design and evaluation of a prosthetic anterior cruciate ligament replacement medical device

Abstract

dc:description.abstract

Rupture of the anterior cruciate ligament (ACL) is a relatively common sports-related injury for which the current treatment is reconstruction with an autograft or allograft. Drawbacks associated with each of the current options would make a prosthetic alternative advantageous, however, artificial ligaments are not widely used, having failed due to lack of biocompatibility and mechanical insufficiencies. To develop the next-generation prosthetic ACL, design control principles were applied including specification of comprehensive design inputs, risk analysis, and verification testing. A design was proposed utilizing polyvinyl alcohol and ultrahigh molecular weight polyethylene, selected for good biocompatibility and mechanical strength and stiffness suitable for ACL replacement. A biomimetic fibrous rope pattern was designed for the intra-articular ligament section of the prosthetic that produced a close match the static tensile behavior of the native ACL and which also demonstrated good resistance to fatigue and creep. A calcium phosphate coating was recommended for the sections of the device lying within the bone tunnel to increase the rate of osseointegration. The proposed design was then evaluated in a computational simulation to assess functional restoration and the effects of installation parameters such as tension and tunnel orientation on knee kinematics. The encouraging results of preclinical verification testing support further in vivo evaluation of the proposed design.

Degree

thesis:*
Department dc:contributor.department
Mechanical Engineering
Grantor dc:publisher
Georgia Institute of Technology
Year dc:date.issued
2012

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Bach, Jason Samuel
Advisors dc:contributor.advisor
  • Ku, David N.
  • Cherkaoui, Mohammed
Committee members dc:contributor.committeemember
  • Cort, Laurent
  • Gleason, Rudolph
  • Guldberg, Robert

Subjects

dc:subject × 6

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1853/47580

Chain of custody

source
Harvested from
Georgia Tech
Base URL
repository.gatech.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Bach, Jason Samuel. Design and evaluation of a prosthetic anterior cruciate ligament replacement medical device. Georgia Institute of Technology, 2012. http://hdl.handle.net/1853/47580