Back to search

Georgia Institute of Technology

Plaque erosion and murine plaque stability: a biomechanical examination of exceptions to the phenomenon of plaque rupture

Abstract

dc:description.abstract

Atherosclerotic plaque disruption leading to thrombosis has traditionally been studied as a rupture of a thin fibrous cap over a lipid-laden necrotic core. However, two noteworthy categories of plaques that do not rupture have presented themselves: 1) in mice, plaque rupture is rare if not absent, and 2) in humans, some plaques erode and form a thrombus without rupturing. Current understanding of the biomechanical differences between plaques that rupture and those that do not is incomplete. In this research, we used patient-specific computational biomechanics tools to study differences among these groups. Lesion-specific solid mechanical modeling of murine plaques revealed that the relative distribution of stresses differs considerably between mice and man. In human vulnerable plaques, peak stresses are on the thin fibrous cap over a necrotic core, but in mice the highest stresses are in the media and adventitia, away from the plaque. Whereas atherosclerotic human arteries usually experience neointima formation around the entire circumference of the vessel, mouse plaques tend to be punctate and adjacent lesion-free regions. The difference in mechanical environment suggests that plaque rupture, if possible in mice, is likely not driven by mechanics in the same manner as humans. Similar mechanical modeling of human ruptured and eroded plaques and comparison to histological staining revealed that ruptured plaques exhibit increased levels of inflammatory markers in response to strain in ruptured plaques, but no such response was observed in plaque erosion. This suggests that treatment of inflammation, a current paradigm for care of atherosclerotic patients, may not be an effective approach to mediate plaque erosion. Computational fluid dynamics modeling of patients with plaque erosion revealed no relation between wall shear stress magnitude or direction, further suggesting that the mechanism of plaque erosion differs considerably from that of plaque rupture. Together, these findings suggest that biomechanics can help explain why not all plaques rupture and that different clinical approaches are necessary to address different phenotypes of lesions.

Degree

thesis:*
Department dc:contributor.department
Biomedical Engineering
Grantor dc:publisher
Georgia Institute of Technology
Year dc:date.issued
2013

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Campbell, Ian Christopher
Advisors dc:contributor.advisor
  • Oshinski, John N.
  • Taylor, W. Robert
Committee members dc:contributor.committeemember
  • Giddens, Don P.
  • Veneziani, Alessano
  • Virmani, Renu
  • Vito, Raymond P.

Subjects

dc:subject × 5

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1853/47741

Chain of custody

source
Harvested from
Georgia Tech
Base URL
repository.gatech.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Campbell, Ian Christopher. Plaque erosion and murine plaque stability: a biomechanical examination of exceptions to the phenomenon of plaque rupture. Georgia Institute of Technology, 2013. http://hdl.handle.net/1853/47741