Back to search

Georgia Institute of Technology

Simulations of pulsatile flow through bileaflet mechanical heart valves using a suspension flow model: to assess blood damage

Abstract

dc:description.abstract

Defective or diseased native valves have been replaced by bileaflet mechanical heart valves (BMHVs) for many years. However, severe complications still exist, and thus blood damage that occurs in BMHV flows must be well understood. The aim of this research is to numerically study platelet damage that occurs in BMHV flows. The numerical suspension flow method combines lattice-Boltzmann fluid modeling with the external boundary force method. This method is validated as a general suspension flow solver, and then validated against experimental BMHV flow data. Blood damage is evaluated for a physiologic adult case of BMHV flow and then for BMHVs with pediatric sizing and flow conditions. Simulations reveal intricate, small-scale BMHV flow features, and the presence of turbulence in BMHV flow. The results suggest a shift from previous evaluations of instantaneous flow to the determination of long-term flow recirculation regions when assessing thromboembolic potential. Sharp geometries that may induce these recirculation regions should be avoided in device design. Simulations for predictive assessment of pediatric sized valves show increased platelet damage values for potential pediatric valves. However, damage values do not exceed platelet activation thresholds, and highly damaged platelets are found far from the valve. Thus, the increased damage associated with resized valves is not such that pediatric valve development should be hindered. This method can also be used as a generic tool for future evaluation of novel prosthetic devices or cardiovascular flow problems.

Degree

thesis:*
Level thesis:degree_level
Doctoral
Department dc:contributor.department
Mechanical Engineering
Grantor dc:publisher
Georgia Institute of Technology
Year dc:date.issued
2013

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Yun, Brian Min
Advisors dc:contributor.advisor
  • Aidun, Cyrus K.
  • Yoganathan, Ajit P.
Committee members dc:contributor.committeemember
  • Neitzel, Paul
  • Taylor, Robert
  • Giddens, Don P.

Subjects

dc:subject × 10

Rights

Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1853/53378

Chain of custody

source
Harvested from
Georgia Tech
Base URL
repository.gatech.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Yun, Brian Min. Simulations of pulsatile flow through bileaflet mechanical heart valves using a suspension flow model: to assess blood damage. Doctoral thesis, Georgia Institute of Technology, 2013. http://hdl.handle.net/1853/53378