Back to search

Georgia Institute of Technology

Nonlinear ultrasonic measurement on cold rolled and sensitized 304 austenitic stainless steel

Abstract

dc:description.abstract

Austenitic stainless steels have a wide range of applications in the energy industry due to their high temperature performance and high corrosion resistance. Type 304 SS, is a widely used stainless steel, but is susceptible to sensitization, the formation of chromium carbide precipitates along the grain boundaries, causing chromium depletion when exposed to a certain temperature, ultimately leading to intergranular stress corrosion cracking (IGSCC). Sensitization preferably tends to occur in the heat affected zone (HAZ) of welds where heat is induced for a certain amount of time during welding. IGSCC is a main cause of the cracking in boiling water reactor piping systems and therefore is of great concern. Nonlinear ultrasound is a nondestructive evaluation method measuring the change of harmonic frequencies over propagation distance quantified by the nonlinearity parameter, β. The research evaluates the changes of microstructure caused by cold work (cold rolling) using two nonlinear ultrasound methods, Rayleigh and longitudinal waves. Moreover it shows the sensitivity of nonlinear ultrasound to sensitization and combines sensitization and cold rolling, then is compared with previous work [20] [6] [17] that investigated just the isolated effect of sensitization, or cold work. The results show that (1) cold work causes significant variations in the nonlinearity parameter which can be attributed to the formation of dislocations and twins as a consequence of the plastic deformation and phase transformation and that (2) cold work has large influences on the sensitization behavior of 304 SS.

Degree

thesis:*
Level thesis:degree_level
Masters
Department dc:contributor.department
Civil and Environmental Engineering
Grantor dc:publisher
Georgia Institute of Technology
Year dc:date.issued
2017

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Geibel, Timm Dennis
Advisor dc:contributor.advisor
  • Jacobs, Laurence J.
Committee members dc:contributor.committeemember
  • Kim, Jin-Yeon
  • Qu, Jianmin

Subjects

dc:subject × 7

Rights

Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1853/60407

Chain of custody

source
Harvested from
Georgia Tech
Base URL
repository.gatech.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Geibel, Timm Dennis. Nonlinear ultrasonic measurement on cold rolled and sensitized 304 austenitic stainless steel. Masters thesis, Georgia Institute of Technology, 2017. http://hdl.handle.net/1853/60407