Back to search

Georgia Institute of Technology

Transient simulation of ammonia-water mixture desorption for absorption heat pumps & optimal control of an electric vehicle cabin air conditioning system

Abstract

dc:description.abstract

Part one of the thesis presents a mathematical framework to simulate the transient response of a desorber for small-capacity ammonia-water absorption heat pumps. The model is based on dynamic analysis of conservation equations and accounts for the thermal capacitances in the heat exchanger wall material and fluid volumes. The numerical solver and its implementation are presented. Improved computational performance is achieved by using advanced solvers for stiff differential-algebraic equations. The model is utilized to predict desorber performance at steady-state conditions and to simulate the transient response of the component to ramping or perturbation of input parameters from steady state. It can also be used to develop reduced-order models suitable for the design of control strategies to optimize system performance. Part two of the thesis presents an optimal control scheme for an electric vehicle cabin air conditioning system. The energy efficient control of a vehicle’s air conditioning (AC) system is of great importance in any modern automobile. However, the goal of maximizing the driving range of battery electric vehicles has increased the interest in sophisticated control strategies. This work presents a control scheme for the air conditioning system of an electric vehicle based on non-linear, constrained optimal control theory with the simultaneous goals of reducing the energy consumption of the AC system and meeting the passengers’ required cabin conditions. Cabin and air system models are derived to define the dynamics of the thermal system. Different formulations of the cabin outlet air temperature available in the literature are explored. From these models, an optimal control problem (OCP) is formulated, with system constraints explicitly considered. The OCP is transformed into a non-linear program using the direct multiple shooting strategy and fourth-order Runge-Kutta method. The open-source IPOPT solver is applied, with the required derivatives provided by the CasADi toolkit. The effectiveness of the proposed optimal control scheme in reducing the energy consumption of the electric vehicle AC system is compared to a simple feedback controller using scenarios with constant and time-varying disturbances.

Degree

thesis:*
Level thesis:degree_level
Masters
Department dc:contributor.department
Mechanical Engineering
Grantor dc:publisher
Georgia Institute of Technology
Year dc:date.issued
2018

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Roeder, Alexander Aryn
Advisor dc:contributor.advisor
  • Garimella, Srinivas
Committee members dc:contributor.committeemember
  • Neitzel, G. Paul
  • Sawodny, Oliver
  • Säger, Ulf

Subjects

dc:subject × 7

Rights

Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1853/60785

Chain of custody

source
Harvested from
Georgia Tech
Base URL
repository.gatech.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Roeder, Alexander Aryn. Transient simulation of ammonia-water mixture desorption for absorption heat pumps & optimal control of an electric vehicle cabin air conditioning system. Masters thesis, Georgia Institute of Technology, 2018. http://hdl.handle.net/1853/60785