Back to search

Georgia Institute of Technology

Anatomical mapping of SEMG signal quality and controllability in skeletal muscle groups for myoelectric prosthesis

Abstract

dc:description.abstract

This thesis presents the hardware implementation for myoelectric signal processing and the experimental evaluation of myoelectric signals to characterize the controllability of the muscle groups in the upper body for controlling the myoelectric prosthetic device. Digital filters were implemented to improve the quality of raw myoelectric signals acquired from the targeted muscle groups. The 5th order median filter implementation provided the reliable noise reduction for the electrophysiological noise observed in the abdominal muscle groups. The real-time onset detection algorithm was implemented to determine the onset and the offset of myoelectric signals and to generate discrete control signals for the prosthetic device. The experiment was designed to investigate the adequacy of utilizing myoelectric signals from the muscle groups in the upper body–deltoids, pectoralis majors, latissimus dorsi, and external obliques–as used in the control of myoelectric prosthetic devices. The voluntary muscle contraction capability of each targeted muscle group was evaluated during the experiment. It was demonstrated that the precise and accurate myoelectric control was achieved using the deltoids muscle group. However, the pectoralis majors and the external obliques were proven to be more appropriate to apply to fast switching on/off control. The combinations of the myoelectric signals acquired from the deltoids and the latissimus dorsi were investigated to generate multiple output stages, and 4 discrete states of myoelectric output were obtained using those muscle groups simultaneously.

Degree

thesis:*
Level thesis:degree_level
Masters
Department dc:contributor.department
Mechanical Engineering
Grantor dc:publisher
Georgia Institute of Technology
Year dc:date.issued
2019

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Jung, Ji Hwan
Advisor dc:contributor.advisor
  • Hammond, Frank L., III
Committee members dc:contributor.committeemember
  • Shinohara, Minoru
  • Wheaton, Lewis A.

Subjects

dc:subject × 2

Rights

Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1853/61697

Chain of custody

source
Harvested from
Georgia Tech
Base URL
repository.gatech.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Jung, Ji Hwan. Anatomical mapping of SEMG signal quality and controllability in skeletal muscle groups for myoelectric prosthesis. Masters thesis, Georgia Institute of Technology, 2019. http://hdl.handle.net/1853/61697