Back to search

Georgia Institute of Technology

A Comparative Analysis of Water-Equivalent Path Length of Tissue Samples using a Fast Monolithic Proton Radiography System

Abstract

dc:description.abstract

Proton therapy has emerged over the past forty years as a clinically viable form of radiation oncology. With low entry dose, a rise to a sharp maximum, and a steep fall-off to zero dose after the "Bragg Peak", proton therapy has proven itself useful particularly with cancers in regions close to sensitive normal tissue. However, proton therapy treatment plans are still produced on x-ray CT scans. Due to fundamentally different natures of interaction, x-ray scans must undergo a conversion to translate Hounsfield Units (HU) to relative stopping power (RSP). This conversion can be inaccurate by up to 4%, and is currently the greatest cause of uncertainty in proton therapy. While there exist several ways around this, directly measuring RSP with proton imaging is the most accurate solution. ProtonVDA, in conjunction with Northern Illinois University, has produced a prototypical proton radiograph and CT scanner compatible with clinical pencil beam scanning (PBS) gantries. In this presentation, I demonstrate recent work on animal tissue samples using this scanner, including pork shoulder, pork ribs, and an in-tact pig head. A comparative analysis of RSP between x-ray CT and proton CT images of these samples is presented, along with sample pencil beam spots measured in the RayStation treatment program.

Degree

thesis:*
Level thesis:degree_level
Masters
Department dc:contributor.department
Mechanical Engineering
Grantor dc:publisher
Georgia Institute of Technology
Year dc:date.issued
2020

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • DeFillippo, Greg James
Advisor dc:contributor.advisor
  • Wang, C.-K. Chris
Committee members dc:contributor.committeemember
  • Erickson, Anna S.
  • Pankuch, Mark

Subjects

dc:subject × 3

Rights

Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1853/64168

Chain of custody

source
Harvested from
Georgia Tech
Base URL
repository.gatech.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

DeFillippo, Greg James. A Comparative Analysis of Water-Equivalent Path Length of Tissue Samples using a Fast Monolithic Proton Radiography System. Masters thesis, Georgia Institute of Technology, 2020. http://hdl.handle.net/1853/64168