The objective of this research was to evaluate the current design specifications for use on prestressed, High Performance Concrete (HPC) bridge girders. An AASHTO Type IV and modified BT-56 girders were constructed with a 10,000 psi HPC to which a composite 7000 psi HPC deck was cast on top. The composite girders were tested in flexure, with the Type IV being tested to failure. The results of the flexure tests showed that the current AASHTO Specification for cracking moment and ultimate capacity are conservative. In addition to flexural testing, each composite girder was studied with respect to the deck contraction induced girder deflection. Each deck and girder were instrumented with strain gauges and string potentiometes. The results of the study indicated the induced deflections are significantly greater than deflections from the deck dead load, and should be considered to accurately predict bridge deflection.

Degree

thesis:*
Department dc:contributor.department
Civil and Environmental Engineering
Grantor dc:publisher
Georgia Institute of Technology
Year dc:date.issued
2005

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Canfield, Scott Robinson
Advisor dc:contributor.advisor
  • Kahn, Lawrence F.
Committee member dc:contributor.committeemember
  • T Russell Gentry

Subjects

dc:subject × 3

Rights

Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1853/7131

Chain of custody

source
Harvested from
Georgia Tech
Base URL
repository.gatech.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Canfield, Scott Robinson. Full Scale Testing of Prestressed, High Performance Concrete, Bridge Girders. Georgia Institute of Technology, 2005. http://hdl.handle.net/1853/7131