Georgia Institute of Technology
Evaluation of Self-Consolidating Concrete for Bridge Structure Applications
Abstract
dc:description.abstractThe goal of this research was to determine whether precast prestressed bridge elements with congested reinforcement could be cast using self-consolidating concrete (SCC) without vibration and yet comply with all parameters of strength, no honeycombing, and void-free surface finish. Eight wall panels and eight BT-72 13-ft long girder sections were fabricated in two precast plants. A qualitative and quantitative evaluation of the surface finish, and homogeneity of the concrete throughout the specimens was performed. Strength, creep, shrinkage and chloride permeability of the SCC field mixes were investigated. Good quality SCC mixes were produced for the walls and the BT-72 girder sections, which completely filled the specimens without the need of internal or external vibration, and resulted in a superior surface finish and a homogenous distribution of the aggregate throughout the section.
Degree
thesis:*- Department dc:contributor.department
- Civil and Environmental Engineering
- Grantor dc:publisher
- Georgia Institute of Technology
- Year dc:date.issued
- 2005
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Horta, Alen
- Advisors dc:contributor.advisor
-
- Kahn, Lawrence F.
- Kurtis, Kimberly E.
- Committee member dc:contributor.committeemember
-
- Lai, James S.