Back to search

Georgia Institute of Technology

Optimizing the Mechanical Design of Wearable Multimodal Biosensing Systems Towards Recording in Dynamic Settings

Abstract

dc:description.abstract

Wearable sensing technologies have demonstrated their capabilities in both clinical and in-lab settings to non-invasively measure health biomarkers and show potential for sensing at home. However, a substantial gap of quality exists within literature between devices which are “wearable” and devices which are truly viable for consumer use. These device form factor limitations can lower user compliance, impair data quality, and impact usability in uncontrolled settings. This work aims to address the mechanical design shortcomings of non-invasive wearable devices by improving their performance and viability for dynamic out-of-lab settings. Specifically, it concentrates on the optimization of a wearable multimodal knee health monitoring system to measure high quality biosignals – joint acoustic emissions, electrical bioimpedance, and joint kinematics – in both clinical as well as at-home and mid-activity settings. The design and hardware enhancements shortened the time required to accurately attach the system onto individuals, increased device robustness, and helped migrate the system towards adhesive-free biosensing. Moreover, an alternate version of the system was optimized for multimodal bioimpedance measurement in out-of-lab settings. This compact design enabled accurate at-home and mid-activity MFBIA which were used to predict muscle force, fatigue, and recovery. The following MS dissertation elaborates upon the optimizations of both form factors and highlights the trials and successes from acquiring health information in previously inaccessible dynamic settings. It also examines future directions for these wearable sensing systems and the potential furthering of their mechanical design. Designing novel wearable devices for use in diverse and uncontrolled environments allows for more acute tracking of health parameters and is a crucial step towards expanding the accessibility and impact of wearable health technologies.

Degree

thesis:*
Level thesis:degree_level
Masters
Department dc:contributor.department
Biomedical Engineering (Joint GT/Emory Department)
Grantor dc:publisher
Georgia Institute of Technology
Year dc:date.issued
2022

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Nichols, Christopher James
Advisor dc:contributor.advisor
  • Inan, Omer T.
Committee members dc:contributor.committeemember
  • Yeo, Woon-Hong
  • Sawicki, Gregory
  • Erturk, Alper

Subjects

dc:subject × 4

Rights

Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1853/72603

Chain of custody

source
Harvested from
Georgia Tech
Base URL
repository.gatech.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Nichols, Christopher James. Optimizing the Mechanical Design of Wearable Multimodal Biosensing Systems Towards Recording in Dynamic Settings. Masters thesis, Georgia Institute of Technology, 2022. https://hdl.handle.net/1853/72603