Abstract
dc:description.abstractThe planned MEC-U facility will house a high-intensity, high-rep-rate short pulse laser capable of accelerating electrons and ions beyond tens of MeV during each experiment. Normal operation of this facility will result in activation of the instrumentation and structure in the experimental hutch. This research aims to quantify the hazards from activation over the lifetime of the MEC-U, and use this data to make informed recommendations from a radiological perspective. After assuming a realistic and conservative operational pattern, the FLUKA Monte Carlo code was used to simulate the activation of the facility. Aluminum alloys, Al-5051, Al-6061, and Al-7075, were tested for the target chamber, and ASTM A36 steel was tested against aluminum alloy Al-6061 for the construction of the surrounding support structure. Results demonstrated that Al-7075 should not be used, as it results in residual dose rates twice as high as the other alloys. Results further demonstrated that steel could be used for the support structure, as it does not result in significantly higher dose rates due to its relatively low magnitude of activation compared to the adjacent target chamber. Following material selection, additional simulations were performed to estimate the yearly effective dose that personnel could receive during normal operations. A set of work schedules were developed in consultation with MEC-U scientists, which were then used to integrate dose rate curves to calculate a cumulative personnel dose to each case schedule. Access to the interior of the target chamber, which is not planned to occur frequently, was added to these estimates separately, as well. With these factors considered, the case of a SLAC scientific staff member working in the MEC-U was estimated to receive 92 mrem in one year without any additional mitigations in place, and technicians were estimated to receive up to 114 mrem in one year. Additionally, estimates are provided for the dose received from handling diagnostic equipment, which will increase these estimates. Safety measures and other mitigations will be subsequently considered to ensure conformity with ALARA principles.
Degree
thesis:*- Level thesis:degree_level
- Masters
- Department dc:contributor.department
- Mechanical Engineering
- Grantor dc:publisher
- Georgia Institute of Technology
- Year dc:date.issued
- 2023
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Connolly, Patrick
- Advisor dc:contributor.advisor
-
- Dewji, Shaheen
- Committee members dc:contributor.committeemember
-
- Rokni, Sayed
- Deo, Chaitanya
Subjects
dc:subject × 5Rights
- Language dc:language.iso
- en_US
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/1853/72758