Georgia Institute of Technology
Micromagnetic Intracochlear Stimulation: Dual-Axial Microcoil Modeling, Fabrication, and Validation
Abstract
dc:description.abstractOver 700,000 cochlear implant users worldwide utilize commercialized cochlear implants that operate using direct current injection from electrodes. Under ideal hearing conditions, cochlear implant users exhibit strong speech perception scores; however, speech recognition is severely impacted by noisy environments, especially when target stimuli are not spatially separated from the noise. Conventional cochlear implant electrode arrays are not able to overcome these obstacles due to subpar stimulation precision. Additionally, the cochlea is filled with a conductive fluid and electrical currents extend to nearby areas, causing a spread of excitation, also impacting user hearing quality. Magnetic stimulation may serve as a solution since magnetic stimulation sites are more localized when compared to electrical stimulation and magnetic fields are impervious to the material properties of the biological environment. The objective of this research project is to develop, characterize, and demonstrate a functional magnetic alternative to conventional cochlear implant electrodes. Microcoils designed for a cochlear implant array were developed to stimulate neural elements with an improved spatial resolution while operating safely within the constraints of the cochlea. Previous reports show that micromagnetic stimulators demonstrate an improved spatial resolution of stimulation sites by comparing the activating functions of electrical and micromagnetic stimulators. The activating function is a metric for determining stimulation sites along an axon. In this work, microcoils were designed using finite-element modeling, and the activating functions were calculated to evaluate the spatial resolution of the microcoil stimulation channels. The fabrication protocol for the unique, biocompatible microcoil is described in detail; moreover, the utilized additive manufacturing processes allow the microcoils to be integrated onto existing cochlear array substrates that minimize insertion trauma. The physical, electrical, and electromagnetic properties of the microcoil components were characterized and validated experimentally, and additional tests were conducted to observe microcoil stability, heating profile, and power characteristics. The microcoils are comprised of a four-turn, 600-μm diameter planar component and a four-turn, 1-mm diameter solenoid component. The activating function spans 1 mm which is 73% narrower than the activating function of conventional electrodes. The microcoils are capable of transmitting 5 nW to target neurons and can be safely operated with a 60 mA maximum amplitude, 5 kHz sinusoidal input pulsed at 1 kHz with a 50% duty cycle for 2.8 hours. Though the input current supplied to the microcoils is significantly greater than the currents utilized by conventional cochlear implant electrodes, further in vivo experimentation is necessary to identify the minimal power requirements to elicit neural responses from target neurons. Improved stimulation precision was achieved with the designed microcoils, observed from theoretical models and simulations. Additionally, in vitro testing methods were developed to characterize the magnitude of transmitted power generated by the microcoils at approximate distances to target neurons. Finally, the methods for fabricating a novel microcoil geometry onto non-planar, flexible, contemporary cochlear array substrates were thoroughly investigated and documented. Furthermore, creating this unique microcoil for such a constrained environment with respect to size and stimulation precision criteria translates heavily to the development of other implantable applications. Ultimately, the microcoils are a promising solution to address the shortcomings of conventional electrodes by improving stimulation channel spatial resolution and, in turn, cochlear implant user pitch perception.
Degree
thesis:*- Level thesis:degree_level
- Doctoral
- Department dc:contributor.department
- Electrical and Computer Engineering
- Grantor dc:publisher
- Georgia Institute of Technology
- Year dc:date.issued
- 2022
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Sarreal, Ressa Reneth S.
- Advisor dc:contributor.advisor
-
- Bhatti, Pamela T.
- Committee members dc:contributor.committeemember
-
- Scott, Waymond
- Inan, Omer
- Frazier, Albert
- Fenton, Flavio
Subjects
dc:subject × 12Rights
- Language dc:language.iso
- en_US
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/1853/72973