Back to search

Georgia Institute of Technology

Thermo-Fluids Perfromance of Helium Cooled Divertors Emphasizing Plate-Type Concepts

Abstract

dc:description.abstract

The magnetic fusion energy (MFE) tokamak reactor, which confines a high temperature plasma within a torus shaped chamber by means of magnetic fields, is one of the most promising and best developed concepts for making nuclear fusion energy possible. One of the challenges in current long-pulse MFE reactors is overcoming the extreme conditions at the first wall of the reactor chamber, where plasma facing surfaces are subject to very high heat fluxes. The divertor is a magnetic field configuration that enables removal of impurities and fusion products from the core plasma by impingement on solid surfaces. The solid target plates of the divertor, which are directly exposed to the plasma and very high heat fluxes of at least 10 MW/m^2, must therefore be cooled so that they do not melt and contaminate the plasma. In addition, about 20% of the total energy produced by the fusion reaction is absorbed by plasma facing surfaces including the divertor targets, and therefore it is important to have a cooling system that can recover this energy. Several designs for cooling the divertor targets have been proposed, and most use helium to cool the back side of the target plates with impinging jets. This doctoral thesis details experimental and numerical studies to estimate the cooling capabilities and required pumping power under prototypical conditions of a number of helium cooled divertor designs, specifically the helium-cooled flat plate (HCFP) divertor, helium-cooled modular divertor with multiple jets (HEMJ), and a “flat design” which is a simplified variant of the HEMJ. Experiments were performed over He mass flow rate ranging from 3 to 10 g/s in helium loops operating at the prototypical pressure of 10 MPa, and elevated helium inlet temperatures as high as 400 °C and incident heat fluxes as high as 8.1 MW/m^2. Numerical simulations using commercial software, validated by these experimental data, complement these experimental studies and are used to extrapolate the thermo-fluids performance to fully prototypical conditions. The results are used to develop “parametric design curves” to allow designers of He-cooled divertors to estimate the maximum allowable heat flux and the corresponding pumping power requirements at different coolant flow rates for a specified limit on the maximum surface temperature of the pressure boundary.

Degree

thesis:*
Level thesis:degree_level
Doctoral
Department dc:contributor.department
Mechanical Engineering
Grantor dc:publisher
Georgia Institute of Technology
Year dc:date.issued
2023

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Lee, Daniel Seokjun
Advisors dc:contributor.advisor
  • Yoda, Minami
  • Abdel-Khalik, Said I.
Committee members dc:contributor.committeemember
  • Joshi, Yogendra
  • Loutzenhiser, Peter
  • Katoh, Yutai

Subjects

dc:subject × 5

Rights

Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1853/73086

Chain of custody

source
Harvested from
Georgia Tech
Base URL
repository.gatech.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Lee, Daniel Seokjun. Thermo-Fluids Perfromance of Helium Cooled Divertors Emphasizing Plate-Type Concepts. Doctoral thesis, Georgia Institute of Technology, 2023. https://hdl.handle.net/1853/73086