Georgia Institute of Technology
Development of forward-viewing high-frequency ultrasound techniques for velocity and wall shear stress estimation in coronary arteries
Abstract
dc:description.abstractAtherosclerotic plaque rupture and erosion are the most important mechanisms resulting in acute coronary syndromes, one of the leading causes of death in the United States. Wall shear stress (WSS), a hemodynamic drag force exerted by viscous blood flowing tangentially to the vessel walls, has been recognized as one of the critical physical factors contributing to atherosclerosis. Low wall shear stress (WSS) is believed to be associated with plaque formation and remodeling, while high WSS is associated with plaque vulnerability. Because the spatial distribution of WSS varies with flow conditions and with vascular anatomy, accurate estimation of local hemodynamics and local WSS distribution in coronary arteries could be used for identifying vulnerable plaques. Non-invasive estimation of 3D blood flow velocity and WSS is challenging due to the requirement for high spatial resolution at deep penetration depths. For this reason, a catheter-based forward-viewing intravascular ultrasound imaging system is being developed to estimate real-time 3D velocity fields and WSS distributions in coronary arteries. In the subsequent chapters, the development of forward-viewing, high-frequency ultrasound techniques for velocity and WSS in coronary arteries is described. The following will be explained: 1) influence of the catheter on velocity estimation in arteries with stenosis when using forward-viewing estimation of 3D blood flow velocity fields, 2) comparison of forward-viewing ultrasound-based velocity and wall shear stress results with computational fluid dynamics results, and 3) evaluation of a motion-compensated, velocity estimation technique in an ex vivo beating porcine heart. In summary, when these techniques are implemented in a forward-viewing, intravascular ultrasound transducer, direct 3D estimation of WSS in coronary arteries could be used to guide intervention in a cardiac catheterization lab.
Degree
thesis:*- Level thesis:degree_level
- Doctoral
- Department dc:contributor.department
- Mechanical Engineering
- Grantor dc:publisher
- Georgia Institute of Technology
- Year dc:date.issued
- 2023
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Kim, Saeyoung Sunny
- Advisor dc:contributor.advisor
-
- Lindsey, Brooks
- Committee members dc:contributor.committeemember
-
- Veneziani, Alessandro
- Arvanitis, Costas
- Oshinski, John
- Emelianov, Stanislav
Subjects
dc:subject × 7Rights
- Language dc:language.iso
- en_US
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/1853/75093