Back to search

Georgia Institute of Technology

The experimental study of electrical breakdown in vacuum encapsulated MEMS devices with deep submicron capacitive electrode gaps

Abstract

dc:description.abstract

This thesis will present for the first time an experimental study of the DC breakdown voltage in vacuum encapsulated capacitive MEMS devices with sub-micrometer capacitive gaps, ranging between 150-250 nanometers. Breakdown of airgaps plays a major role in MEMS device reliability when operating at high DC voltages and high-power levels. Our work mainly focuses on the observation of physical breakdown effects on wafer-level encapsulated MEMS devices incorporating bulk acoustic wave (BAW) capacitive square and disk resonators fabricated using the HARPSS process. The characterization work involves measurement of breakdown voltage as a function of gap size and vacuum pressure.

Degree

thesis:*
Level thesis:degree_level
Masters
Department dc:contributor.department
Electrical and Computer Engineering
Grantor dc:publisher
Georgia Institute of Technology
Year dc:date.issued
2023

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Matthews, Justin Ellis
Advisor dc:contributor.advisor
  • Ayazi, Farrokh
Committee members dc:contributor.committeemember
  • Ansari, Azadeh
  • Ghalichechian, Nima

Subjects

dc:subject × 4

Rights

Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1853/75162

Chain of custody

source
Harvested from
Georgia Tech
Base URL
repository.gatech.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Matthews, Justin Ellis. The experimental study of electrical breakdown in vacuum encapsulated MEMS devices with deep submicron capacitive electrode gaps. Masters thesis, Georgia Institute of Technology, 2023. https://hdl.handle.net/1853/75162