Georgia Institute of Technology
An in vitro Blood Loop Circuit to Assess Thromboresistance with High Shear Rates
Abstract
dc:description.abstractThrombosis on blood contacting artificial materials is a common problem for medical devices. The development of an in vitro test of thromboresistance may aid in the development of better medical devices without the sacrifice and expense of large mammals. Such tests should encompass recent understanding of thrombosis beyond coagulation to assess platelet-rich thrombi that are dominant in arterial blood flow. Recent studies have shown that such platelet rich thrombi form under high shear conditions to elongate the joining protein von Willebrand factor. This study endeavors to address the intricate challenges associated with thrombogenicity of materials, particularly in high shear rates environments expected in arteries. A pivotal aspect of the study involves a novel thrombus circuit designed to replicate the high shear rate conditions in arteries, providing a platform for comprehensive evaluation of thrombogenic potential for arterial catheters. The choices underlying the design and construction of this circuit are outlined, reflecting an effort to test for thrombogenicity under physiologically relevant arterial hemodynamics. An in vitro flow loop was designed to avoid the limitation of low and medium shear conditions used in previous in vitro test systems. Blood flow conditions mimicked the high flow rates expected in the human femoral artery. Whole human blood with a small amount of heparin was used for the in vitro loop while porcine blood was used for the animal model in accordance with ISO/NAVI standards. The endpoint for the test was direct observation of thrombus formation on the catheter or on the surrounding blood vessel. A comparative analysis between in vitro and in vivo results revealed that the equivalent levels of thromboresistance were seen for both the in vitro and in vivo tests. Over the one-hour duration of the tests, the in vitro circuit matched the porcine catheter exposure to yield equivalent thromboresistance. Thus, the blood loop circuit is a promising alternative tool for assessing thromboresistance of arterial catheters. Overall, this master’s thesis contributes to advancing the design of bench tests to assess biological thromboresistance without sacrificing multiple animals under relevant arterial conditions that may induce platelet-rich clots.
Degree
thesis:*- Level thesis:degree_level
- Masters
- Department dc:contributor.department
- Mechanical Engineering
- Grantor dc:publisher
- Georgia Institute of Technology
- Year dc:date.issued
- 2024
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Dodart, Raphaelle
- Advisor dc:contributor.advisor
-
- Ku, David N.
- Committee members dc:contributor.committeemember
-
- Forest, Craig R.
- Costandi, Peter
Subjects
dc:subject × 6Rights
- Language dc:language.iso
- en_US
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/1853/75302