Back to search

Georgia Institute of Technology

Green Infrastructure Best Management Practices: Performance of Vegetated Filter Strips Designed for Infiltration and Sorptive Amendments

Abstract

dc:description.abstract

Urbanization causes degradation in the natural ability of a watershed to mitigate stormwater runoff, which results in increased water volume and pollutant loads discharging to natural waterways. To minimize that impact, the design of green infrastructure for stormwater control mimics the pre-construction hydrology of a developed area using best management practices (BMPs) designed with three primary goals: minimizing runoff flowrate to reduce flooding and erosion; maximizing pollutant deposition to reduce discharge to natural waterways including groundwater; and increasing groundwater recharge and with an added filtration component. Because stormwater BMP permitting can result in differences in prioritized design parameters, inconsistent efficiency measurements, and an extremely wide range of quantification methods, this work focused on bringing uniformity to the design and performance of the vegetated slope that is designed for stormwater control. In this study, an analytical model was developed to incorporate both overland flow and soil infiltration in the BMP’s partially saturated soils to optimize designs for lower stormwater discharge volumes and longer residence time. Additionally, field and laboratory studies were performed to study the transport and deposition of solid phase contaminants (soil and rubber) to quantify solids deposition profiles throughout the length of a vegetated slope. Dissolved heavy metal transport through the vegetated slope was evaluated based on the adsorption characteristics of the deposited sediment profile of the BMP. Results showed that the flow rate could be reduced by up to 19% in silty sandy soils in unsaturated conditions when accounting for infiltration. Further, 99% of solids were deposited in the first 2 meters of a vegetated slope, which agreed well with modeled trapping efficiencies based on particle diameter and density. Adsorption analysis showed that Piedmont soils sorbed relatively small concentrations of heavy metals; however, incorporating even small percentages (by mass) of a highly sorbent component (activated carbon) in the soil regime increased both infiltration and adsorptive capacity, substantially increasing the filter strip’s performance.

Degree

thesis:*
Level thesis:degree_level
Doctoral
Department dc:contributor.department
Civil and Environmental Engineering
Grantor dc:publisher
Georgia Institute of Technology
Year dc:date.issued
2024

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Stypulkowski, Amy Lynnae
Advisor dc:contributor.advisor
  • Burns, Susan E.
Committee members dc:contributor.committeemember
  • Frost, David
  • Dai, Sheng
  • Sturm, Terry
  • Glass, Jennifer

Subjects

dc:subject × 5

Rights

Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1853/77743

Chain of custody

source
Harvested from
Georgia Tech
Base URL
repository.gatech.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Stypulkowski, Amy Lynnae. Green Infrastructure Best Management Practices: Performance of Vegetated Filter Strips Designed for Infiltration and Sorptive Amendments. Doctoral thesis, Georgia Institute of Technology, 2024. https://hdl.handle.net/1853/77743