Abstract
dc:description.abstractThe work described in this dissertation focuses on competitive binding of synthetic oligonucleotides. Aptamers are single-stranded oligonucleotides capable of binding to non-nucleotide targets with high specificity and sensitivity, and can be used in a variety of applications including diagnostics, therapeutics, and molecular sensing. The traditional approach for aptamer screening known as SELEX (Systematic Evolution of Ligands by EXponential enrichment) requires PCR amplification of bound sequences following each incubation cycle; however, this introduces sequence bias and unwanted side-products. In order to mitigate these issues, the Milam lab developed a PCR-free alternative to SELEX known as CompELS (Competition-Enhanced Ligand Selection). While previous CompELS experiments have yielded aptamer candidates, the process remains a “black box” as sequences are only identified at the end of the screening. Two separate CompELS screening experiments are discussed in this dissertation: one against a biological target (Fc protein) and against with a material target (graphene). The Fc protein is the conserved region of IgG antibodies, therefore Fc-binding aptamers could serve as “universal handles” for antibody capture and purification. Graphene is an allotrope of carbon, whose unique electronic properties are useful in sensing applications. Both of these CompELS experiments used “barcoded” screening libraries which could be used to determine which cycle of CompELS a particular sequence was added to the target. The results of these barcoded CompELS experiments indicated that there was indeed an exchange of bound sequences occurring at each successive cycle. Further discussion of the CompELS is presented in Chapter 2, Chapter 4, and Chapter 5. Following CompELS—or any aptamer screening experiment—it is necessary that the aptamer candidates be sequenced. Incredible progress in DNA sequencing has been made in the past two decades; however, these techniques are largely optimized for the sequencing of genomic DNA rather than the random library sequences used in aptamer screening. While genomic DNA fragments vary in length and composition, aptamer screening library sequences do not: each sequence consists of a random segment flanked by fixed base segments. This uniformity in base composition of aptamer screening libraries results in a dramatically decreased sequencing yield. The work presented in Chapter 3 provides insight into the causes of these sequencing challenges, as well as suggestions for mitigating these issues. In addition to the aptamer research discussed above, this dissertation also presents a platform for the detection of specific nucleic acid sequences using synthetic oligonucleotides. This project began during the early months of the Covid-19 pandemic, when the reagents and supplies for qPCR-based testing methods were in short supply. This goal of this project was to develop a method a PCR-free method of detecting viral RNA sequences using flow-cytometry. This detection platform relied on double-stranded oligonucleotide probe systems: one strand (complementary to the target nucleic acid sequence of interest) was conjugated to the surface of a microsphere and possessed a fluorescent tag, while its hybridization partner possessed a quencher molecule. The two strands comprising a dsprobe system must be chosen such that the duplex remains stable under normal conditions, while still allowing for displacement of the quencher-capped strand by the target nucleic acid sequence. When the fluorescently-tagged probe sequence and its quencher-capped hybridization partner are hybridized, the system has a low fluorescence signal; however, when the target nucleic acid sequence displaces the quencher-capped strand, the system has a high fluorescence signal. Chapter 6 describes the various probe systems that were screened for sensitivity and specificity, resulting in the selection of a particular probe system for further characterization. Titration studies revealed that while the selected probe system was highly responsive to the target nucleic acid sequence, the fluorescence response of the system was unexpectedly low. The work presented in Chapter 7 revealed that the quencher molecules used in this study (Iowa Black quenchers) exhibited significantly longer range quenching effects than anticipated. As a result of this long-range quenching effect, even slightly incomplete displacement of the quencher-capped strands resulted in significantly decreased fluorescence signal.
Degree
thesis:*- Level thesis:degree_level
- Doctoral
- Department dc:contributor.department
- Materials Science and Engineering
- Grantor dc:publisher
- Georgia Institute of Technology
- Year dc:date.issued
- 2025
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Adams, Mary Catherine
- Advisor dc:contributor.advisor
-
- Milam, Valeria T.
- Committee members dc:contributor.committeemember
-
- Brettmann, Blair
- Jang, Seung Soon
- Finn, MG
- Naik, Rajesh
Subjects
dc:subject × 3Rights
- Language dc:language.iso
- en_US
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/1853/77873