Back to search

Georgia Institute of Technology

Design, Modeling, Imaging, and Control of a Robotically Steerable Transcatheter Delivery System

Abstract

dc:description.abstract

Mitral regurgitation affects 1.7% of the general population and 10% of those over 75, representing the most prevalent valvular heart disease. Transcatheter mitral valve repair (TMVr), increasingly preferred for nearly half of MR patients who are non-surgical candidates, currently utilizes manually operated devices that expose clinical staff to increased radiation, require experienced operators to facilitate intuitive compensations of the joints, and offer limited precision compared to potential robotic systems. This work introduces a robotically steerable transcatheter delivery system for treating mitral regurgitation, demonstrating effective positioning and orientation of the implant with respect to the mitral valve leaflets and extensive testing to validate its clinical relevance. Over five generations of the robotic transcatheter system, the steerable end tip design is optimized for effective implant deployment and the actuation system is refined for adequacy and compactness. Relevant clinical features are incorporated to enable intravascular surgery, intuitive control is demonstrated via joystick, and precise implant delivery is validated using existing TMVr procedure imaging modalities. The kinematics of the steerable end are derived, and a control system is presented. Since pure kinematics does not capture all the physical phenomena of a long catheter system, research has focused on characterizing tendon elongation, tendon sheath friction, and the influence of catheter configuration and tendon pre-tension. Furthermore, stiffness optimization of the bending joint with super elastic reinforcements minimizes deflection in pulsatile flow while ensuring compliant manipulation by the steerable outer sheath. Moreover, the study demonstrates the integration of a new real-time pose estimation technique utilizing ultrasound imaging for joint space control, and accurate positioning in conjunction with fluoroscopic imaging along with automatic trajectory generation. This is aimed at reducing trauma to the heart tissue during implant deployment. Extensive feasibility testing across phantom benchtop experiments, ex vivo heart models, and in vivo studies confirms the system’s efficacy, highlighting its readiness for clinical adoption and significant advancement in robotic catheter technology.

Degree

thesis:*
Level thesis:degree_level
Doctoral
Department dc:contributor.department
Mechanical Engineering
Grantor dc:publisher
Georgia Institute of Technology
Year dc:date.issued
2024

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Nayar, Namrata Unnikrishnan
Advisor dc:contributor.advisor
  • Desai, Jaydev P.
Committee members dc:contributor.committeemember
  • Lindsey, Brooks D.
  • Chen, Yue
  • Wood, Levi B.
  • Ueda, Jun

Subjects

dc:subject × 4

Rights

Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1853/78589

Chain of custody

source
Harvested from
Georgia Tech
Base URL
repository.gatech.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation