Georgia Institute of Technology
Single-Phase Hybrid Cooling and Integrated Fluidic Heat Spreader Solutions for Compact SiC Power Modules
Abstract
dc:description.abstractThe growing demand for high power density in electrified transportation is accelerating the shift from silicon to wide-bandgap semiconductors—such as silicon carbide MOSFETs— due to their superior electrical characteristics. However, legacy silicon-based packaging limits the performance benefits of these devices. To address this challenge, this thesis introduces a novel integrated cooling approach using multifunctional cold plates that simultaneously serve electrical and thermal functions. While dielectric coolants enable such integration, their low thermal conductivity can lead to excessive fluid heating near device junctions, shifting thermal constraints from the device to the coolant under high power density. Design limitations such as reduced layers and limited access for top-side fluid ports further exacerbate these challenges, especially in homogeneous cooling structures lacking local flow control. Thus, a hybrid cooling architecture combining triply periodic minimal surfaces (TPMS) with micropillars is introduced, targeting hot spots and enhancing flow mixing where most needed. Validated simulations reveal unique flow structures generated by TPMS–pillar combinations under diagonal flow and multiple heat sources—such as swirling motion, flow alignment, and acceleration through high-curvature channels—which disrupt thermal boundary layers and locally enhance convective heat transfer. To further address heat spreading challenges, an integrated fluidic heat spreader with a cold plate was developed and tested using flow visualization experiments, revealing distinct evaporation, boiling, and condensation patterns under vacuum as it approaches steady-state and dry-out conditions. To provide early predictive capability for dry-out limit investigation, three-dimensional (3D) transient conjugate two-phase models were developed using a unified Volume of Fluid (VOF) approach, combining liquid-filled micropillar wicks and a vapor core within a single fluid domain. The models captured time-evolving fluid dynamics and liquid meniscus morphology, revealing critical mechanisms such as dynamic rewetting, bubble coalescence, early vapor film development, and localized dry-out. Capillary pressure variations linked to dynamic meniscus deformation served as predictive indicators of dry-out onset, offering insight into the performance limits of the spreader.
Degree
thesis:*- Level thesis:degree_level
- Doctoral
- Department dc:contributor.department
- Mechanical Engineering
- Grantor dc:publisher
- Georgia Institute of Technology
- Year dc:date.issued
- 2025
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Muslu, Ahmet Mete
- Advisor dc:contributor.advisor
-
- Joshi, Yogendra
- Committee members dc:contributor.committeemember
-
- Zhang, Zhuomin
- Smet, Vanessa
- Bakir, Muhannad
- Guyenot, Michael
Subjects
dc:subject × 11Rights
- Language dc:language.iso
- en_US
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/1853/82020