Georgia Institute of Technology
Design of an In-Vivo Gamma Ray Body Scanner for Assaying Biodistribution of Inhaled Radionuclide Contamination in Warfighters
Abstract
dc:description.abstractIn response to radiological or nuclear scenarios in which warfighters may be exposed to contamination, prompt assessment of internal radiation contamination is critical for triage assessment and administration of medical countermeasures. The 2×2 NAIS NaI(Tl) scintillation detectors were selected to construct a scanning system to measure internalized gamma-ray emitting radionuclide contamination in warfighters. The detector responses were simulated using PHITS Monte Carlo radiation transport code and validated through benchmark measurements with Polymethyl Methacrylate (PMMA) slab phantoms and laboratory check sources to cover a broad spectrum of gamma energies. Upon verification, mesh-type anthropomorphic phantoms representing different height and weight groups were used to examine correlations of the chest wall thicknesses (CWTs) in adult female and male military warfighters with the gamma counting efficiencies of detectors positioned at the thoracic region for direct lung contamination. Next, a fourteen-detector grid covering critical body areas was implemented in PHITS, and gamma-ray depositions from critical radionuclides were simulated for all organs of interest. Biokinetic modeling data from International Commission on Radiological Protection Publication 130 were incorporated to determine the time-dependent retentions in the organs and the detector peak counting efficiencies. To optimize the number and placement of detectors for contamination assessment, an efficiency-based optimization algorithm was developed using simulated gamma flux distributions across pseudo planes placed on the anterior and posterior sides of each phantom. These planes were divided into fine mesh grids, which allows the identification and classification of hotspots. For each combination of radionuclide, time post-inhalation, and phantom morphometry, detector combinations yielding the most optimal counting statistics were selected. The decision level, minimum detectable activity, and minimum detectable committed effective dose were analyzed for the selected detection configuration. Mathematical formulations of the initial inhaled activity, 50-year committed dose, and 30-day organ-specific doses were proposed based on Monte Carlo radiation transport simulations using patient-dependent anatomical models and biokinetic models, and a software graphical user interface (GUI) streamlining the proposed procedures was developed for in-field triage application.
Degree
thesis:*- Level thesis:degree_level
- Doctoral
- Department dc:contributor.department
- Mechanical Engineering
- Grantor dc:publisher
- Georgia Institute of Technology
- Year dc:date.issued
- 2025
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Wei, Yi
- Advisor dc:contributor.advisor
-
- Dewji, Shaheen
- Committee members dc:contributor.committeemember
-
- Biegalski, Steven
- Wang, Chris
- Zhang, Fan
- Bolch, Wesley E.
Subjects
dc:subject × 4Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/1853/82043