Back to search

Georgia Institute of Technology

Mechanism and Scenarios Leading to Thrombosis in Arteriovenous Grafts for Dialysis Patients

Abstract

dc:description.abstract

With more than 2 million patients worldwide being treated with end stage renal disease, consistent dialysis treatment is imperative to sustaining life while awaiting a transplant. The most common cause of access site failure is thrombosis. While much of the literature has assumed these thromboses are caused by coagulation, the high shear rates of blood flow experienced in an Arterio-Venous Fistula (AVF) may cause occlusion by Shear-Induced Platelet Aggregation (SIPA). Aside from the high flow rates in AVF, we hypothesized that a focal stenosis may create high shear rates sufficient to trigger thrombotic occlusion by SIPA. We further hypothesized that a focal stenosis could form within a PTFE graft or at the PTFE-venous anastomosis due to mechanical compression or kinking. A simplified fluid mechanic analysis was done to identify the possible range of shear rates that could be expected throughout the system and a focal stenosis. Collaborative work with Dr. Menon used more specific Computational Fluid Dynamics (CFD) to specify local shear at the venous anastomosis. To demonstrate biological thrombosis, an in vitro model was built using a PTFE graft and perfused with human whole blood for 4.5 hours. The resultant clot locations were compared with CFD estimates of focal shear rate and histology performed to assess the composition of the thrombi for platelets vs fibrin and red blood cells. Our hemodynamic analysis predicted that a focal stenosis of >50% in the vein and >35% in the graft would be expected to increase jet shear rates to above 3,000/s within the graft and in the downstream vein. CFD results verify these shear estimates for pulsatile flow and localize the high shear to about a 7.5 x 4.5 mm zone in the area of jet impingement downstream. The in vitro model illustrated several kink possibilities within common anatomies for graft placement. Stenoses were also easily formed at the anastomosis due to torquing, even with seemingly perfect stitches. The soft mechanical xi structure of the PTFE graft was easily compressed, even under arterial pressures, to create a transient stenosis. Thus, a cause of late graft failure from thrombosis may be triggered by a transient or fixed stenosis creating sufficiently high shear rates for SIPA occlusion. Lastly, we could create macroscopic platelet-rich thrombi at the venous anastomosis in the in vitro system with reasonable hemodynamic AVF parameters. Consideration of these pathophysiologic mechanisms of hemodynamically induced thrombosis may aid in surgical planning to reduce the likelihood of focal stenoses in AVFs.

Degree

thesis:*
Name thesis:degree_name
Biomedical Engineering, MS
Department thesis:degree_department
Biomedical Engineering (Joint GT/Emory Department)
Grantor
Georgia Institute of Technology
Year dc:date.issued
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Jensen, Anna
Advisor dc:contributor.advisor
  • Ku, David N.
Committee members dc:contributor.committeemember
  • Gleason, Rudolph
  • Menon, Karthik
ORCID person:identifier.orcid

Rights

Language dc:language.iso
English

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1853/82227

Chain of custody

source
Harvested from
Georgia Tech
Base URL
repository.gatech.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Jensen, Anna. Mechanism and Scenarios Leading to Thrombosis in Arteriovenous Grafts for Dialysis Patients. Georgia Institute of Technology, 2026. https://hdl.handle.net/1853/82227