Back to search

University of Glasgow

Improvements to the [13C]MTG breath test for measuring fat digestion

Abstract

dc:description.abstract

There is a need for a robust, non-invasive clinical test to assess fat digestion, especially in children with cystic fibrosis. Labelling of substrates with 13C enables investigation of their digestion, absorption and subsequent metabolism. The mixed triacylglcerol (MTG) 13C-breath test is an indirect measure of fat digestion, and therefore exocrine pancreatic function. Cystic fibrosis is the commonest cause of pancreatic insufficiency in children. 13C-breath tests are particularly attractive for use in children because they are non-invasive, and pose no radiation hazard. MTG is a synthetic triacylglycerol (1,3 distearyl 2-[1-13C] octanoyl-glycerol). Pancreatic lipases preferentially hydrolyse triacylglycerol at the sn-1 and -3 positions, releasing 13C-labelled octanoate which is rapidly absorbed and oxidised with the generation of 13CO2. Quantitation of tracer excretion requires knowledge of the volume of distribution of the 13C-labelled tracer as well as quantity of ingested dose and abundance in breath CO2. In 13C-breath tests, labelled CO2 originating from oxidation of the tracer is diluted by endogenously produced CO2 from metabolic processes. Therefore knowledge of CO2 production rate (VCO2) is required. A resting value based on basal metabolic rate is often assumed, but if subjects are not at rest and in the postprandial state throughout the test, this will be an underestimate of the true CO2 production rate and therefore underestimate the quantity of tracer excreted. The MTG breath test has not been widely adopted because it lacks discrimination due to its poor specificity. The hypothesis tested in this study is that the poor specificity of the [13C]MTG breath test is due to lack of knowledge of the true carbon dioxide production rate during the test. (Abstract shortened by ProQuest.).

Degree

thesis:*
Level dc:type.qualificationlevel
PhD
Grantor dc:publisher.institution
University of Glasgow
Year dc:date.issued
2004

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Slater, Christine

Rights

Language dc:language
en

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
University of Glasgow
Base URL
theses.gla.ac.uk/cgi/oai2
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Slater, Christine. Improvements to the [13C]MTG breath test for measuring fat digestion. PhD thesis, University of Glasgow, 2004. https://doi.org/10.5525/gla.thesis.71085