Back to search

University of Glasgow

An investigation into the wake flow behind circular cylinders fitted with slat devices

Abstract

dc:description.abstract

In this experimental study, two types of slat models were used to fit on a circular cylinder; a fully slatted (slats placed evenly around the cylinder) and a partially slatted model (slat system leaving larger openings at the front and at the rear of the cylinder). Hot wire anemometric technique was used to study the wake flow within the downstream region between 3 cylinder diameters to 6 cylinder diameters, measured from the centre of the model, and in a plane about 6.5 diameters from the free end of the model. The model has a length-to-diameter ratio of 10, and the Reynolds number for the experiment was about Re=3x10.

Degree

thesis:*
Level dc:type.qualificationlevel
MSc(R)
Grantor dc:publisher.institution
University of Glasgow
Year dc:date.issued
1983

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Kokkalis, Anastasios

Rights

Language dc:language
en

Chain of custody

source
Harvested from
University of Glasgow
Base URL
theses.gla.ac.uk/cgi/oai2
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Kokkalis, Anastasios. An investigation into the wake flow behind circular cylinders fitted with slat devices. MSc(R) thesis, University of Glasgow, 1983.