University of Glasgow
An Investigation of the Wear of Human Enamel and Dental Ceramics
Abstract
dc:description.abstractThere has been an increase in the use of ceramic restorative materials in modern dentistry. This is perhaps because of continuous patients' demands for dental restorations that simulate the appearance of their natural teeth. Although ceramic restorations provide good aesthetics, clinicians were always concerned about their abrasiveness against the natural dentition. The objective of this study was to investigate the wear of human enamel and dental ceramics using a wear machine that simulated the chewing cycle. The machine provided an impact action followed by sliding motion of a tooth specimen onto the surface of various restorative materials. Tooth specimens were prepared from the buccal cusp of extracted mandibular premolars, A total of four dental ceramic systems were tested in the study. These were Vitadur Alpha porcelain (aluminous porcelain), Vita Omega porcelain (bonded-to-metal porcelain), Duceram-LFC (hydrothermal low fusing ceramic); and Cerec Vita Mark II (machinable ceramic). Cast gold was also tested for comparison. Overall, throughout the study, a load of 40N was used with a cycle rate of 80 cycles per minute for a total of 25000 cycles. The amount of wear was determined by measuring the cusp height reduction of the tooth using a reflex microscope, and the depth of wear track on the surface of restorative materials using a Dektak 3 ST surface profile measuring system. After the wear test, specimens from both tooth and material were subjected to scanning electron microscopy for qualitative evaluation.
Degree
thesis:*- Level dc:type.qualificationlevel
- PhD
- Grantor dc:publisher.institution
- University of Glasgow
- Year dc:date.issued
- 1997
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Al-Hiyasat, Ahmad Saleh
Rights
- Language dc:language
- en