Back to search

University of Glasgow

Hardware prototyping and thermal simulations of strip sensor, and simulation of transmission lines for the LHCb VELO upgrade

Abstract

dc:description.abstract

The LHCb experiment based at CERN’s Large Hadron Collider (LHC) particle accelerator is undergoing upgrades to replace end of life detectors and take advantage of the luminosity upgrades that the LHC machine is gaining. The VErtex LOcator (VELO) is a particle tracking sub detector of LHCb and its upgrade is designed to record up to an order of magnitude more data from proton-proton collision events. During the development of the upgrade, silicon strip sensors and pixel detectors were investigated as options. A prototype of the strip sensor was assembled with readout hardware to characterise its performance. Cooling methods were considered and thermal simulations were performed to verify that cooling an irradiated silicon strip sensors after 50 fb−1 of integrated luminosity is viable. Using the technologically least aggressive and hence easier to implement cooling solution required liquid CO2 to be below -18◦C to avoid thermal runaway, the upgraded CO2 cooling infrastructure is capable of -30◦C hence thermal control is viable. The silicon pixel sensor technology was chosen for its superior track reconstruction performance as the upgrade technology. It requires around 2.85 Tbits/s of data to be transferred for processing off-site. The sensor’s readout electronics require multiple parallel transmission lines capable of each carrying 5.12 Gbits/s of data without significant signal loss and also have sufficient flexibility to accommodate the 3 cm lateral movement of the VELO sub detector halves. A flexible copper multilayer ribbon cable design, so called “flex cables”, is a compact solution, with a thickness just over 400 µm where each transmission line is 1200 µm wide. Simulations were performed to find the optimal characteristic differential impedance and transmission properties which were used to guide the prototype development. Comparisons of impedance measurements against real world prototype versions showed a systematic bias of around 10 Ω that could be explained by various factors explored within. Comparisons of transmission versus frequency showed good agreement between simulation and measurement. The flex-cable design has been finalised and the VELO upgrade is being assembled in preparation for on site installation into the LHCb detector.

Degree

thesis:*
Level dc:type.qualificationlevel
MSc(R)
Grantor dc:publisher.institution
University of Glasgow
Year dc:date.issued
2022

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Longstaff, Iain

Rights

Language dc:language
en

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
University of Glasgow
Base URL
theses.gla.ac.uk/cgi/oai2
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Longstaff, Iain. Hardware prototyping and thermal simulations of strip sensor, and simulation of transmission lines for the LHCb VELO upgrade. MSc(R) thesis, University of Glasgow, 2022. https://doi.org/10.5525/gla.thesis.82756