Back to search

University of Glasgow

Computational methods for augmenting the echocardiographic assessment of low-flow, low-gradient aortic valve stenosis

Abstract

dc:description.abstract

Aortic stenosis (AS) is the most common valvular disease requiring intervention in adults in developed countries. One of its most diagnostically challenging subtypes is low-flow low-gradient (LFLG) AS, characterised by discordant echocardiographic grading criteria. Current guidelines recommend dobutamine stress echocardiography (DSE) to resolve diagnostic uncertainty; however, DSE is often inconclusive and carries procedural risks. This research investigates whether resting echocardiographic recordings alone can distinguish true-severe from pseudo-severe LFLG AS. First, statistical analyses and classical machine learning (ML) techniques were applied to standard and novel echocardiographic predictors to assess their ability to separate severity grades and flow states. The results show that the decision boundaries derived from concordant AS cases do not generalise well to LFLG AS. Although ML models achieved 79.3% accuracy in synthetic data generated from concordant AS, performance decreased when evaluated in the LFLG AS cohort in both rest and stress states. Second, a novel strain imaging pipeline was developed to estimate three-dimensional myocardial deformation from 2D triplanar echocardiographic data. This enabled calculation of 3D strain parameters over time without full 3D acquisitions. The global and segmental longitudinal strain values did not show significant differences between the 3D and triplanar methods, confirming the validity of the pipeline. A qualitative analysis also suggested that regional strain values were lower in patients with severe LFLG AS. Finally, deep learning (DL) models that combine transformer-based feature extractors with multiple-instance learning were trained on a public dataset for AS severity classification. The test accuracy showed marginal improvements in the public data set with an average improvement of 2.16% over the predefined test sets, and generalisation to clinical data from patients with concordant AS achieved a balanced accuracy of 67.5%, compared to 62.5% from previous models. Additionally, the model performance in LFLG AS was assessed under resting or both resting and stress states.

Degree

thesis:*
Level dc:type.qualificationlevel
PhD
Grantor dc:publisher.institution
University of Glasgow
Year dc:date.issued
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Illyes, Marcell

Subjects

dc:subject × 3

Rights

Language dc:language
en

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
University of Glasgow
Base URL
theses.gla.ac.uk/cgi/oai2
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Illyes, Marcell. Computational methods for augmenting the echocardiographic assessment of low-flow, low-gradient aortic valve stenosis. PhD thesis, University of Glasgow, 2026. https://doi.org/10.5525/gla.thesis.86089