Back to search

University of Glasgow

Flexible self-powered piezoelectric pressure sensors based on chitosan for wearable health monitoring

Abstract

dc:description.abstract

With the rapid development of the Internet of Things, wearable electronics and smart medical technologies, flexible pressure sensors are evolving towards being lightweight, self-powered, biocompatible and environmentally sustainable. Piezoelectric pressure sensors can directly convert mechanical stimuli into electrical signals, enabling dynamic pressure sensing without the need for an external power source. As a result, they are widely used in fields such as electronic skin, health monitoring, human-machine interaction, and intelligent robotics. However, the piezoelectric materials currently in widespread use primarily rely on lead-containing piezoelectric ceramics or fluorinated polymers, which generally suffer from issues such as insufficient biocompatibility, lack of environmental degradability and limited flexibility. Meanwhile, although bio-based materials offer excellent sustainability, they are typically used only as flexible substrates or support layers, and their potential as active piezoelectric materials has not yet been fully explored. To address these issues, this thesis focuses on the bio-derived piezoelectric polymer chitosan and related polymer systems, systematically conducting research into the material design, performance optimisation and wearable applications of flexible, self-powered piezoelectric pressure sensors, with a particular emphasis on exploring the relationships between material composition, microstructure, piezoelectric properties and device functionality. Firstly, using chitosan as the active piezoelectric material, flexible piezoelectric films were fabricated via a solution cast-filming method, and a sandwich-type piezoelectric pressure sensor was constructed. The study demonstrated that pure chitosan is capable of stable dynamic pressure sensing and exhibits good flexibility, bio-sourced properties and solubility. A 50 μm thick device achieved a pressure sensitivity of 32.25 mV/kPa and a frequency sensitivity of 316.79 mV/Hz, its dynamic response characteristics could mimic the rapid response of Pacinian corpuscles to pressure stimuli, thereby establishing a benchmark system for subsequent research into bio-based piezoelectric materials. Subsequently, to enhance the piezoelectric properties of chitosan, organic-inorganic composite systems were developed using ZnO and BaTiO3 nanoparticles, respectively. The ZnO composite significantly improved the piezoelectric coefficient and output performance, specifically, the 15 wt.% ZnO composite devices achieved a pressure sensitivity of 70.71 mV/kPa, a frequency sensitivity of 471.43 mV/Hz and a piezoelectric coefficient of 16 pC/N. A pressure sensor array was subsequently prepared, enabling target recognition, pressure distribution detection, gesture recognition and wireless data transmission. In the BaTiO3 system, lead-free ferroelectric nanoparticles further enhanced the electromechanical coupling capability, the 15 wt.% chitosan-BaTiO3 composite achieved a pressure sensitivity of 276.07 mV/kPa, a frequency sensitivity of 2564.29 mV/Hz and an output of 24.9 V and was successfully integrated into a wireless smart insole to demonstrate a proof of concept for gait monitoring. Concurrently, the study systematically analysed the effects of nanoparticle dispersion, crystal structure and interfacial interactions on piezoelectric performance, revealing an intrinsic relationship between enhanced output performance and material flexibility. Finally, to further explore the application of highly biocompatible polymers in piezoelectric sensing, Parylene C films of varying thicknesses were fabricated using chemical vapour deposition (CVD) and employed as an active piezoelectric layer in flexible pressure sensing. The study found that as the film thickness increased, its piezoelectric coefficient and output performance improved simultaneously. The 45 μm devices achieved a pressure sensitivity of 87.62 mV/kPa, a frequency sensitivity of 580.95 mV/Hz and a response time of 12 ms, whilst maintaining stable output over more than 1,200 cycles and during 10 consecutive days of testing. Furthermore, the Parylene C pressure sensor array was integrated into a wireless smart glove, enabling real-time monitoring of hand-object interactions and wireless data transmission. In summary, this thesis has established a series of flexible, self-powered piezoelectric pressure-sensing material systems based on bio-derived polymers, validated the feasibility of chitosan and its composites as active piezoelectric layers, systematically revealed the influence of material composition, interface structure and microstructure on piezoelectric performance, and completed the validation of wearable systems such as wireless smart gloves, smart insoles and pressure-sensing arrays. These research findings not only enrich the design theory of bio-based flexible piezoelectric materials but also provide a new material system and technological foundation for the development of sustainable electronic skin, smart health monitoring, human-computer interaction and next-generation green wearable electronic devices.

Degree

thesis:*
Level dc:type.qualificationlevel
PhD
Grantor dc:publisher.institution
University of Glasgow
Year dc:date.issued
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Wang, Zhao

Subjects

dc:subject × 1

Rights

Language dc:language
en

Chain of custody

source
Harvested from
University of Glasgow
Base URL
theses.gla.ac.uk/cgi/oai2
Last updated
2026-11-21
Source record
OAI-PMH GetRecord
citation

Wang, Zhao. Flexible self-powered piezoelectric pressure sensors based on chitosan for wearable health monitoring. PhD thesis, University of Glasgow, 2026.