Back to search

Gothenburg University

Transpulmonary pressure during mechanical ventilation

Abstract

dc:description.abstract

Background: Mechanical ventilation can aggravate lung injury by repetitive opening and closing of lung units, overdistention and undue pressure on pulmonary structures. Guidelines exist for lung protective ventilation, but individualized ventilator settings, based on partitioning of respiratory mechanics in pulmonary and chest wall complex components, would be beneficial. This thesis examines the current practice of respiratory care in the Nordic countries and evaluates a method to assess lung volume changes during mechanical ventilation. A new concept to measure lung and chest wall elastance and determine transpulmonary pressure during mechanical ventilation is validated. Methods: Clinical practice concerning adjunct therapies to mechanical ventilation were addressed in a web-based survey performed in Nordic intensive care units. Changes in lung volume (DeltaEELV) were determined by spirometry, where the first ten breaths after a PEEP change were studied. The sum of the differences of inspiratory and expiratory tidal volumes was calculated, with correction for offset. The method was validated in a lung model and in 12 patients with simultaneous measurement of lung volume changes by electrical impedance tomography (EIT). PEEP induced changes in DeltaEELV, airway and esophageal pressures were studied both in an animal model and in 12 ventilated patients. Results: One-third of the patients had more than 12 disconnections from the ventilator circuit during 24 hours, with great variations in the individual lowest and highest oxygenation ratios (PaO2/FiO2). The spirometric method showed good agreement with known volume changes in the lung model and with estimated lung volume changes by EIT. PEEP increase resulted in only modest increase in esophageal pressure. The increase in transpulmonary pressure was closely related to increase in PEEP. Lung elastance determined from change in PEEP divided by DeltaEELV was closely correlated with that obtained from esophageal pressure measurements. Conclusion: Routine care of ventilated patients leads to repeated derecruitment episodes due to disconnections of the ventilator circuit by frequent use of aerosol therapy and endotracheal suctioning. Spirometric measurements of inspiratory-expiratory tidal volumes as well as impedance changes by EIT can be used to estimate PEEP-induced changes in lung volume. The minimal increase in esophageal pressure after a PEEP increase indicate that the abdomen and chest wall gradually yields and adapts when the diaphragm is pushed in caudal direction. As a consequence, PEEP increase will cause a corresponding increase in transpulmonary pressure. This may explain why lung elastance can be determined from the change in PEEP divided by the change in lung volume without the need for esophageal pressure measurements.

Degree

thesis:*
Department dc:contributor.department
Institute of Clincial Sciences. Department of Anesthesiology & Intensive Care Medicine
Year dc:date.issued
2013

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Grivans, Christina

Subjects

dc:subject × 8

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
ISBN
978-91-628-8832-9
Dc Identifier Department
SA

Chain of custody

source
Harvested from
Gothenburg University
Base URL
gupea.ub.gu.se/oai/request
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Grivans, Christina. Transpulmonary pressure during mechanical ventilation. 2013. https://hdl.handle.net/2077/34396