Back to search

University of Patras

Ακριβής προσδιορισμός παραμέτρων ποιότητας δέσμης ακτινοβολίας στην ακτινοθεραπεία με τη βοήθεια επαναληπτικών υπολογιστικών μεθόδων monte carlo

Abstract

dc:description

The present study aimed to develop a user code to simulate linear accelerator heads using Monte Carlo code EGS4. The McRad /EGS4 code was originally run on a DEC 300-M600 Alfa workstation (Digital Equipment) using the FORTRAN compiler running under VMS. In the present work the code has been compiled and installed on a PC. The two implementations have been compared and there were no significant statistical differences between the results The McRad/EGS4 code has been used to calculate the energy spectra on different points across the field of Saturne 25 / 41 . The energy spectra have been used to investigate the change quality of the photon beam due to the present of the flattening filter. These calculations were made along the central ray and at 10, 17, and 24 cm off axis rays. The analysis of the results showed that as the distance from the central axis increases from 0 to 24 cm the mean energy of the 6 MV beam decreases 26.2%, for the 12 MV 19.7%, 28% for the 15 MV and 30.4% for the 23 MV. If the flattening is not present these values are 7.1%, 12.7%, 14% and 18.6% respectively. The Monte Carlo simulation of two linear accelerators, Saturne 25 and 41, allowed us to study the influence of electron contamination in various therapeutic energies and in different geometries. The contribution of the secondary contamination electrons on the surface dose is 16% for 6 MV and 12 MV, 6% for 15 MV and 17% for 23 MV. The energy spectra of electrons coming from the flattening filter and the air below it are completely different. The air produces electrons of low energies. The mean energies of these spectra vary from 1 MeV to 2 MeV depending on the nominal energy of the photon beam. The secondary electrons generated by the flattening filter produce a wide energy spectrum with mean energies of the same order of the bremsstrahlung spectrum. The flattening filter absorbs the secondary electrons generated in the target, the primary collimator and the air inside the head.

Degree

thesis:*
Grantor dc:publisher
University of Patras
Year dc:date
2002

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Μαλαταρά, Γεωργία
  • Malatara, Georgia

Subjects

dc:subject × 18

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/13462

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Μαλαταρά, Γεωργία; Malatara, Georgia. Ακριβής προσδιορισμός παραμέτρων ποιότητας δέσμης ακτινοβολίας στην ακτινοθεραπεία με τη βοήθεια επαναληπτικών υπολογιστικών μεθόδων monte carlo. University of Patras, 2002. http://hdl.handle.net/10442/hedi/13462