Abstract
dc:descriptionMedical film digitizers play an important transitory role as digital to analogue bridges inradiology. Their use requires performance evaluation to assure high medical image quality. The aim of this work was to design and develop a quality assurance procedure for medical film digitizers. A complete quality control protocol is presented, based on a set of test objects adaptive to the specifications of various digitizers. The protocol includes parameters such as uniformity, input-output response, noise, geometric distortion, spatial resolution, low contrast discrimination, film slippage and light leakage, as well as associated measurement methods. The applicability of the proposed protocol was demonstrated with two types of medical film digitizers, a CCD and a laser one. The potential value of this protocol is also discussed. The main advantages are its completeness and adaptability to digitizer specifications, by means of the proposed test objects. In addition, it is easily applicable even for daily tests, if suitable software for digital image display and measurements is available. This protocol can be utilized for quality assurance purposes, as well as to cover the needs of acceptance tests of new equipment, status tests, and tests for comparison purposes. A comparative evaluation of three test objects, which can be used for quality control of medical film digitizers was also performed. The test objects used in this study were the 'SMPTE pattern' which is provided by all manufacturers of digital medical imaging systems, together with the systems, the 'PACS Test Pattern' which is commercially available, and an adaptive test object called ΑΤΟ, designed using a tool developed in the Department of Medical Physics of University of Patras. A quality control procedure on a Lumiscan 75 medical image digitizer was performed with the use of each of these three test objects. The results of the measurements are presented. The advantages and the disadvantages of each of the objects in testing medical image digitizers are indicated. The evaluation of the results showed that ΆΤΟ' meets all the needs, quantitative and qualitative, of the proposed quality control protocol and presents the most advantages of all three, followed by 'PACS test pattern' while 'SMPTE pattern' is rated in the third place. Two points of interest that should be stated here are, firstly that 'SMPTE pattern' has not been designed at the beginning although it has been used later for this purpose, and secondly that their availability isinversely proportional to their rating in this evaluation. The minimum desired characteristics of an ideal test object, is described as a result of this study. Proposals for further work are stated at the end of the text.
Degree
thesis:*- Grantor dc:publisher
- University of Patras
- Year dc:date
- 2002
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Efstathopoulos, Efstathios
- Ευσταθόπουλος, Ευστάθιος
Subjects
dc:subject × 12Rights
- Language dc:language
- eng
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/13468